Immergas VICTRIX EXTRA 12 PLUS Instructions And Recommendations page 100

Table of Contents

Advertisement

Id
Parameter
Parameter
Stand-by/OFF
P.8
configuration
External probe
P.9
reading
correction
P.10
Not used
Configuration
P.11
Input 1 (40-41)
Configuration
P.12
Input 2 (14-15)
Configuration
P.13
Input 3 (1-2)
ImgBus Input
P.14
Configuration
(44-41)
Probe configu-
P.15
ration (47-48)
(*) : when connecting a DIM or zones control unit to terminals 21, 40 and 41, parameterP.11 must be set at 2.
100
Description
0: Antifreeze, anti-block active
1: Antifreeze off and anti-block active
2: Antifreeze anti-block off
3: Not used
If the reading of the external probe is not correct it is possible
to correct it in order to compensate any environmental
factors.
-
Setting a value other than zero is not accepted if the function
is already present in another input (*):
0: OFF
1: zone 1 room thermostat generates central heating request
together with remote control (logic in AND)
2: room thermostat zone 1 generates a heating central
heating request as an alternative to the remote control (Logic
in OR)
3: room thermostat zone 2 generates a heating central
heating request as an alternative to the remote control (Logic
in OR)
4: Safety thermostat (low temperature)
See notes P.11
Not used
Setting a value other than zero and one is not accepted if
already present in another input:
0: Not used
1: ImgBus
2: TA zone 1
3: TA zone 2
4: Safety thermostat (low temperature)
0: OFF/Storage tank probe
1: Not available
2: Not available
Range
Default
0-3
0
-9..9 °C
0
-
-
0-4
1
0-4
4
-
-
0-4
1
The value is
automatically
selected
0-2
depending on
the value set
in parameter
A.0
Value
customized