Smart Energy Management Status

This screen is displayed only when Smart Energy Management is enabled. The screen shows energy details 
of the site:
S i t e
L i m i t :
S i t e
P r o d :
S i t e
E x p o r t :
S e l f - c o n s u m e :
 
Site Limit: The limit that was defined for the site
l
 
Site Prod: The power produced by the site
l
 
Site Export: The power that is fed into the grid
l
 
Self-consume: The PV power consumed by the site
l
For more information, refer to the Export Limitation Application Note, available on the 
SolarEdge website at http://www.solaredge.com/files/pdfs/products/feed-in_limitation_
application_note.pdf.

Power Control Status

This screen is displayed only when Power Control is enabled (available from 
communication board (CPU) firmware version 2.7xx/3.7xx and later).
P W R
C T R L :
P W R
L i m i t :
C o s P h i :
P o w e r
P r o d :
 
 
PWR CTRL: The power control status: 
l
 
REMOTE - Communication with the RRCR or smart energy manager is confirmed/validated. 
o
 
LOCAL - The power is controlled locally (e.g. by a fixed limit), or this inverter limits the PV power 
o
production to its relative portion of the feed-in power limit, as a result of disconnected 
communication with the smart energy manager. If this status appears, check the communication 
to the smart energy manager or the communication to the meter. 
 
PWR Limit: The inverter maximum output power set by one of the power limiting options: 
l
 
RRCR 
o
 
Smart energy manager (Feed-in limitation) 
o
 
P(f)
o
 
P(U)
o
 
Q(U) 
o
 
Cos Phi: The ratio between active to reactive power 
l
 
Power Prod: The power produced by the inverter 
l
For more information, refer to the Power Control Application Note, available on the 
SolarEdge website at http://www.solaredge.com/files/pdfs/application_note_power_
control_configuration.pdf.
Single Phase Inverter with HD-Wave Technology Installation MAN-01-250-1.2
7 . 0 k W
1 0 . 0 k W
4 . 0 k W
6 . 0 k W
R E M O T E
1 0 . 0 4
k W
0 . 9
7 0 0 0 W
Chapter 5: Configuring the Inverter