ID Status
Vdc_O: Power optimizer output voltage
l
Vdc_I: Power optimizer input voltage (module voltage)
l
I_in: Power optimizer input current
l
Temp: Power optimizer temperature
l
ID Status
This screen displays the inverter software version and the country to which the inverter is configured.
D S P 1 / 2 : 1 . 0 2 1 0 / 1 . 0 0 3 4
C P U : 0 0 0 3 . 1 9 x x
C o u n t r y : E S P
ID: The inverter ID.
l
DSP 1/2: The DSP digital control board firmware version
l
CPU: The communication board firmware version
l
Country: the current country setting
l
Server Communication Status
S e r v e r : L A N
S t a t u s :
x x x x x x x x
< E R R O R
NOTE
If the connection method is CDMA (referred to as "Cellular" in the status screens) or GSM, the server
screen is replaced with the Cellular or GSM status screens (see Status Screens - Operational Mode on
page 38 and GSM Status on page 42).
Server: The method of connection to the SolarEdge monitoring platform.
l
S_OK: The connection to the SolarEdge monitoring platform is successful (should appear only if the i s
l
connected to the server).
Status: Displays OK if the inverter established successful connection and communication with the
l
specified server port/ (LAN, RS485, Wi-Fi or ZigBee Plug-in).
xxxxxxxx: Eight-bit Ethernet communication connection status: A string of 1s and 0s is displayed. 1
l
indicates OK, 0 indicates an error.
Error message, according to failure. Refer to Error Codes on page 55.
l
IP Status
This screen describes the Ethernet configuration: IP, Mask, Gateway and MAC address (Media Access
Control) of the Inverter.
I P
1 9 2 . 1 6 8 . 2 . 1 1 9
M S K
2 5 5 . 2 5 5 . 2 5 5 . 0
G W
1 9 2 . 1 6 8 . 2 . 1
M A C
0 - 2 7 - 0 2 - 0 0 - 3 9 - 3 6
40
Single Phase Inverter with HD-Wave Technology Installation MAN-01-250-1.2
< S _ O K >
< O K >
M E S S A G E >