Before installing the appliance, ensure it has been
delivered in perfect condition; if in doubt, contact
the supplier immediately. Packing materials (staples,
nails, plastic bags, polystyrene foam, etc.) constitute a
hazard and must be kept out of the reach of children.
If the appliance is installed inside or between cabinets, ensure
sufficient space for normal servicing; for the minimum instal-
lation distances refer to Fig. 3.
It is just as important that the intake grids and exhaust
terminals are not obstructed.
It is recommended to check that no flue gas recirculation
is found in the air sample points (0.5% maximum per-
mitted CO
).
2
Keep all flammable objects away from the appliance (paper,
rags, plastic, polystyrene, etc.).
The minimum distance for exhaust pipes from flammable
materials must be at least 25 cm.
Do not place household appliances underneath the boiler as
they could be damaged if the safety valve intervenes (if not
conveyed away by a draining funnel), or if there are leaks from
the hydraulic connections; otherwise, the manufacturer cannot
be held responsible for any damage caused to the household
appliances.
For the aforementioned reasons, we recommend not placing
furnishings, furniture, etc. under the boiler.
In the event of malfunctions, faults or incorrect operation, turn
the appliance off immediately and contact an authorised com-
pany (e.g. the Authorised Technical Assistance centre, which
has specifically trained staff and original spare parts). Do not
attempt to modify or repair the appliance alone.
Any modification to the appliance that is not explicitly indicated
in this section of the booklet is forbidden.
Installation Standards:
- This boiler can be installed outdoors in
a partially protected area. A partially
protected area is one in which the appliance is
not exposed to the direct action of the weather
(rain, snow, hail, etc..).
- Installation in places with a fire risk is pro-
hibited (for example: garages, closed parking
stalls), gas appliances and relative flue ducts,
flue exhaust pipes and combustion air intake
pipes.
- Installation on the vertical projection of
cooking hobs is forbidden.
- Installation is also prohibited in places/
environments that constitute com-
mon parts of office condominiums
such as stairs, cellars, entrance halls,
attics, lofts, escape routes, etc. if they are
not located inside technical compartments
under the responsibility of each individual
building and only accessible to the user (for
the features of the technical compartments,
see the technical standards in force).
- These boilers are not suitable for installation
on walls made of combustible material.
N.B.: wall mounting of the boiler must guarantee
stable and efficient support for the boiler. The plugs
(standard supply) are only to be used to fix the boil-
er to the wall; they only ensure adequate support if
inserted correctly (according to technical standards)
in walls made of solid or semi-hollow brick or block.
In the case of walls made of hollow bricks or blocks, parti-
tions with limited static properties, or in any case walls other
than those indicated, a static test must be carried out on the
mounting system.