Concentric Horizontal Kit Installation - Immergas MINI EOLO 24 3 E Instructions And Warnings

Hide thumbs Also See for MINI EOLO 24 3 E:
Table of Contents

Advertisement

1.14 Concentric horizontal kit installation.

Type C configuration, sealed chamber and fan assisted.
Installation of this terminal is governed by standards contained
in local building regulations, as amended.
N.B.: in addition to the traditional "Ø60/100 horizontal kit"
there is also a specific "Ø60/100 Star" version, with the same
measurements and equivalent head loss.
This terminal is connected directly to the outside of the building
for air intake and flue exhaust. The horizontal kit Ø 60/100 can be
installed with the rear, right side, left side or front outlet.
• External grid. N.B.: for safety purposes, do not obstruct the
boiler intake-exhaust terminal, even temporarily.
Horizontal intake - exhaust kit Ø60/100. Kit assembly (Fig. 14):
install the bend with flange (2) onto the central hole of the boiler
inserting the gasket (1) and tighten using the screws included in
the kit. Couple the terminal pipe (3) with the male end (smooth)
into the female end of the bend (with lip seals) up to the stop;
making sure that the internal wall sealing plate and external wall
sealing plate have been fitted, this will ensure sealing and joining
of the elements making up the kit.
2
1
3
4 5
The kit includes:
N°1 - Gasket (1)
N°1 - Concentric bend 90° (2)
N°1 - Intake/Exhaust concentric pipe
Ø60/100 (3)
N°1 - Internal wall sealing plate (4)
N°1 - External wall sealing plate (5)
• Application with rear outlet (Fig. 15). The 970 mm pipe
length enables routing through a maximum thickness of 770
mm. Normally the terminal must be shortened. Calculate the
measurement by the sum of these values: Wall thickness + indoor
extension + outdoor extension. The minimum indispensable
projection values are given in the figure.
• Application with side outlet (Fig. 16). Using the horizontal
intake-exhaust kit, without the special extensions, enables
routing through a wall thickness of 725 mm with the left side
outlet and 645 with the right side outlet.
• Extensions for horizontal kit. The Ø 60/100 horizontal intake-
exhaust kit can be extended up to a max. horizontal length of
3000 mm, including the terminal with grille and excluding
the concentric bend leaving the boiler. This configuration
corresponds to a resistance factor of 100. In these cases the special
extensions must be requested.
Connection with 1 extension (Fig. 17). Max. distance between
vertical boiler axis and external wall is 1855mm.
Connection with 2 extensions (Fig. 18). Max. distance between
vertical boiler axis and external wall is 2805mm.
C
12
14
C
12
16
C
12
15
C
12
17
C
12
18
19