Immergas MINI EOLO 24 3 E Instructions And Warnings page 16

Hide thumbs Also See for MINI EOLO 24 3 E:
Table of Contents

Advertisement

FAN POWER: 30W (Fig. 9).
Diaphragm
Pipe extension in metres Ø 60/100 horizontal
(ref. 1 fig. 9)
Ø 85
Ø 83
WITHOUT
Diaphragm
Pipe extension in metres Ø 60/100 vertical
(ref. 1 fig. 9)
Ø 85
Ø 83
WITHOUT
Diaphragm
Pipe extension in metres Ø 80/125 horizontal
(ref. 1 fig. 9)
Ø 85
Ø 83
WITHOUT
Diaphragm
Pipe extension in metres Ø 80/125 vertical
(ref. 1 fig. 9)
Ø 85
Ø 83
WITHOUT
Diaphragm
Pipe extension in metres Ø 80 divided
(ref. 2 fig. 9)
Ø 20.5
From 0.5 to 15
Ø 15
From 15 to 35
Diaphragm
Pipe extension in metres Ø 80 divided
(ref. 2 fig. 9)
Ø 20.5
Ø 15
WITHOUT
1
Key:
1 - Concentric flue extraction diaphragm
2 - Divided flue extraction diaphragm
16
From 0 to 0.5
From 0.5 to 1.5
Exceeding 1.5
From 0 to 2.2
From 2.2 to 3.7
Exceeding 3.7
From 0 to 0.5
From 0.5 to 4.6
Exceeding 4.6
From 0 to 5.4
From 5.4 to 9.5
Exceeding 9.5
intake
exhaust
1
1
intake
exhaust
1
From 0.5 to 8
1
From 8 to 16
1
Exceeding 16
2
FAN POWER: 33W / 39W (Fig. 10).
Diaphragm
(fig. 10)
Ø 40
Ø 41.5
WITHOUT
Diaphragm
(fig. 10)
Ø 40
Ø 41.5
WITHOUT
Diaphragm
(fig. 10)
Ø 40
Ø 41.5
WITHOUT
Diaphragm
(fig. 10)
Ø 40
Ø 41.5
WITHOUT
Diaphragm
(fig. 10)
Ø 40
Ø 41.5
WITHOUT
Diaphragm
(fig. 10)
Ø 40
Ø 41.5
WITHOUT
* The values for maximum length are considered with 1 metre of
exhaust pipe and the remaining on intake.
DIAPHRAGM
9
Pipe extension in metres Ø 60/100 horizontal
From 0 to 0.5
From 0.5 to 1.5
Over 1.5
Pipe extension in metres Ø 60/100 vertical
From 0 to 2.2
From 2.2 to 3.2
Over 3.2
*Extension in metres horizontal pipe Ø 80
with two bends
From 0 to 17
From 17 to 24
Over 24
*Extension in metres
vertical pipe Ø 80
without bends
From 0 to 22
From 22 to 29
Over 29
Pipe extension in metres Ø 80/125 horizontal
From 0 to 0.5
From 0.5 to 3.3
Over 3.3
Pipe extension in metres Ø 80/125 vertical
From 0 to 5.4
From 5.4 to 8.1
Over 8.1