In any configuration do no install the indoor unit and outdoor unit at altitudes above 2000 m.
Installation standards
This appliance can be installed outdoors in a partially protected area.
By partially protected area, we mean one in which the unit is not directly exposed to the elements (rain, snow, hail, etc.).
This type of installation is possible when permitted by the laws in force in the appliance's country of destination.
Do not install on the vertical projection of hobs.
Do not install in places/rooms that constitute public areas of apartment buildings, internal
stairways or other escape routes (e.g. floor landings, entrance halls, etc.).
To prevent electrocution, fire or injury, always switch off the unit, disable the protective switch
and, if smoke escapes or if the unit is extremely noisy, contact the Authorised After-Sales
Technical Assistance Centre.
Do not install near sources of heat.
Using specific kits, the indoor unit can be paired with other Immergas products and installed inside an outdoor wall using the specific
Container Super Trio recessed frame or mounted on an indoor wall in the Domus Container Super Trio.
Pay attention not to generate sparks as follows:
– Do not remove the fuses while the unit is on.
– Do not unplug the unit while it is on.
It is recommended to install the outlet high up. Lay the cables in such a way that they do not get
tangled.
Installing the wall recessed frame kit must guarantee the indoor unit stable, efficient support.
The recessed frame kit ensures appropriate support only if installed correctly (according to the rules of good practice), following the in-
structions on its instructions leaflet.
The recessed frame for the indoor unit is not a supporting structure and must not replace the wall removed. It is necessary to position the
boiler inside the wall.
For safety reasons against any leaks it is necessary to plaster the housing compartment of the indoor unit in the brick wall.
Wall mounting of the indoor unit must guarantee stable and efficient support for the genera-
tor.
The plugs (standard supply) are only to be used to fix the indoor unit to the wall; they only ensure adequate support if inserted correctly
(according to technical standards) in walls made of solid or semi-hollow brick or block. In the case of walls made from hollow brick or
block, partitions with limited static properties, or in any case walls other than those indicated, a static test must be carried out to ensure
adequate mount.
These appliances are used to heat water to below boiling temperature in atmospheric pressure.