Integration menu.
Id
Parameter
Parameter
DHW integra-
I 01
tion enabling
System
I 02
integration
enabling
DHW max wait
I 03
time
Central heating
I 04
max wait time
Simultaneous
I 08
D.H.W.
DHW activation
I 09
temperature
System
I 10
activation
temperature
Outdoor unit
I 11
operating hours
Heating
integration
I 12
resistance hours
of operation
DHW integra-
tion resistance
I 13
hours of
operation
Preheat
function
I 15
enabling
temperature
Description
Allows you to enable an alternative power source (AL) to
integrate domestic hot water heating
Using this function, you can enable an alternative (AL) or
simultaneous (CO) power source to integrate heating system
central heating.
Establishes the maximum amount of time before activating
DHW integration.
Establishes the maximum amount of time before activating
central heating integration.
Enables the simultaneous operation in DHW mode and
room air conditioning mode
Establishes the outdoor temperature under which DHW
integration is enabled
Establishes the outdoor temperature under which system
integration is enabled
Displays the hours of operation performed by the outdoor
unit
Displays the hours of operation of the central heating
integration resistance (optional)
Displays the hours of operation of the DHW integration
resistance (optional)
If system integration is enabled, this is the temperature
below which the preheat function is activated
Range
Default
OFF - AL
OFF
OFF - AL - CO
OFF
1 - 255
240
minutes
1 - 255
120
minutes
OFF - ON
ON
-25 ÷ 35°C
-15
-25 ÷ 35°C
-15
-
-
-
-
-
-
14 ÷ 25°C
20
Value
customized
73