Immergas MAGIS PRO 12 V2 Instructions And Recommendations page 72

Hide thumbs Also See for MAGIS PRO 12 V2:
Table of Contents

Advertisement

Id
Parameter
Parameter
Outdoor
temperature for
Zone 3 low
R 25
temperature
zone min
cooling flow
Outdoor
temperature for
Zone 3 low
R 26
temperature
zone max
cooling flow
Zone 3 low
temperature
R 27
zone minimum
cooling
Zone 3 low
temperature
R 28
zone maximum
cooling
72
Description
Establishes the outdoor temperature at which to have the
maximum flow temperature of zone 3
Establishes the outdoor temperature at which to have the
maximum flow temperature of zone 3
Establishes the outdoor temperature at which to have the
maximum flow temperature of zone 3
Establishes the outdoor temperature at which to have the
maximum flow temperature of zone 3
Range
Default
20 ÷ 40
35
20 ÷ 40
25
5 ÷ 20
18
5 ÷ 25
20
Value
customized

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magis pro 14 v2Magis pro 16 v2

Table of Contents