Heat regulation menu.
Id
Parameter
Parameter
R 01
External probe
Outdoor
temperature for
R 02
max CH flow
zone 1
Outdoor
temperature for
R 03
min CH flow
zone 1
Zone 1
R 04
maximum
central heating
Zone 1
R 05
minimum
central heating
Outdoor
temperature for
R 06
max zone 2 CH
flow mixed zone
Outdoor
temperature for
R 07
min zone 2 CH
flow mixed zone
Zone 2 mixed
R 08
zone maximum
central heating
Zone 2 mixed
R 09
zone minimum
central heating
Zone 1 outdoor
temperature for
R 10
minimum
cooling flow
70
Description
Defines if and which external probe is used to manage the
system.
OFF = no external probe used
OU = external probe on outdoor unit
IU = optional external probe connected to the indoor unit
Establishes the outdoor temperature at which to have the
maximum flow temperature of zone 1.
Establishes the outdoor temperature at which to have the
minimum flow temperature of zone 1.
Defines the maximum flow temperature in zone 1 room
central heating mode
Defines the minimum flow temperature in zone 1 room
central heating mode
Establishes the outdoor temperature at which to have the
maximum flow temperature of zone 2
Establishes the outdoor temperature at which to have the
minimum flow temperature of zone 2
Defines the maximum flow temperature in zone 2 room
central heating mode
Defines the minimum flow temperature in zone 2 room
central heating mode
Establishes the maximum outdoor temperature at which to
have the minimum flow temperature in zone 1 cooling mode
Range
Default
OFF - OU - IU
OU
-15 ÷ 25 °C
-5
-15 ÷ 25 °C
25
20 ÷ 55
45
20 ÷ 55
25
-15 ÷ 25 °C
-5
-15 ÷ 25 °C
25
20 ÷ 55
40
20 ÷ 55
25
20 ÷ 40
35
Value
customized