Immergas MAGIS PRO 12 V2 Instructions And Recommendations page 67

Hide thumbs Also See for MAGIS PRO 12 V2:
Table of Contents

Advertisement

Id
Parameter
Parameter
Relay 1
P 03
(optional)
Relay 2
P 04
(optional)
Relay 3
P 05
(optional)
External probe
P 07
correction
Gen. DHW
P 11
setpoint offset
DHW electric
P 12
resistance
tripping offset
T max anti-Le-
P 13
gionella
P 14
T max DHW
Description
The indoor unit is set-up for functioning with the relay
P.C.B. (optional), which can be configured
0 = Off
1 = DHW recirculation
2 =General alarm
3 = Central heating / cooling mode active
4 = Puffer mode active
5 = Dehumidifier zone 3
The indoor unit is set-up for functioning with the relay
P.C.B. (optional), which can be configured
0 = Off
1 = DHW recirculation
2 =General alarm
3 = Central heating / cooling mode active
4 = Puffer mode active
5 = Zone 3 mixing valve closing
The indoor unit is set-up for functioning with the relay
P.C.B. (optional), which can be configured
0 = Off
1 = DHW recirculation
2 =General alarm
3 = Central heating / cooling mode active
4 = Puffer mode active
5 = Zone 3 mixing valve opening
If the reading of the external probe is not accurate, it is
possible to correct it in order to compensate any environ-
mental factors.
The DHW flow setpoint of the generator is calculated by
adding P11 to the DHW setpoint
Call an Authorised After-Sales Technical Assistance Centre
Maximum time to perform anti-Legionella function
Maximum time to perform DHW function
Range
Default
0 ÷ 4
0
0 ÷ 4
0
0 ÷ 4
0
-9 ÷ 9 K
0
2 ÷ 30 °C
10
5 ÷ 50 °C
5
1 - 24 hours
3
1 - 24 hours
5
Value
customized
67

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magis pro 14 v2Magis pro 16 v2