Immergas MAGIS PRO 12 V2 Instructions And Recommendations page 66

Hide thumbs Also See for MAGIS PRO 12 V2:
Table of Contents

Advertisement

Id
Parameter
Parameter
Zone 2 room
A 32
thermostat
Zone 3 room
A 33
thermostat
Room probe
A 35
modulation
Heating/
A 39
Cooling contact
Zone 1 heating /
A 41
cooling enable
Zone 2 heating /
A 42
cooling enable
Zone 3 heating /
A 43
cooling enable
Dehumidifier
A 51
flow setpoint
zone 1
Dehumidifier
A 52
flow setpoint
zone 2
Dehumidifier
A 53
flow setpoint
zone 3
66
Description
Defines the temperature control in zone 2
Defines the temperature control in zone 3
In the presence of Zone Remote panel, configured in RP,
enables modulation with room probe
Enables the Heating/Cooling function by means of a dry
contact
Allows to determine heating, cooling mode or both of zone 1
Allows to determine heating, cooling mode or both of zone 2
Allows to determine heating, cooling mode or both of zone 3
Setpoint used by the machine for dehumidification demand
on zone 1 without cooling demands present
Setpoint used by the machine for dehumidification demand
on zone 2 without cooling demands present
Setpoint used by the machine for dehumidification demand
on zone 3 without cooling demands present
Range
Default
RT = Room
thermostat
RP - Remote
panel
RT
RPT =
Remote panel
with
Thermostat
RT = Room
thermostat
RP - Remote
panel
RT
RPT =
Remote panel
with
Thermostat
OFF - ON
ON
OFF - ON
OFF
HT / CL / H
H – C
– C
HT / CL / H
H – C
– C
HT / CL / H
H – C
– C
15 ÷ 25 °C
20
15 ÷ 25 °C
20
15 ÷ 25 °C
20
Value
customized

Advertisement