Parameters And Information Menu - Immergas MAGIS PRO 12 V2 Instructions And Recommendations

Hide thumbs Also See for MAGIS PRO 12 V2:
Table of Contents

Advertisement

2.6

PARAMETERS AND INFORMATION MENU

Pressing the "MENU" button (2), the display cyclically shows the "Data" menu, "User" menu and a menu protected by a "0000" access
code with the first flashing digit reserved for a qualified technician.
To access an individual menu, once it appears, press the "OK" button (1).
To scroll through the menu items and to edit the values, use the heating temperature control buttons (5). Pressing the "OK" button (1)
confirms the parameter, while pressing the "ESC" button (3) goes back to the previous menu or exits.
A minute after the last operation, the system automatically exits any of the menus.
The menus of the control panel, found in the booklet, refer to rev. 6.0 of the P.C.B. firmware.
Data Menu.
Parameter ID
D 03
Storage tank unit temperature (if paired with a storage tank unit)
D 04
Value calculated for system setting
D 05
Set value for the DHW set (if paired with a storage tank unit)
Outdoor temperature (if the outdoor unit external probe is connected or if the optional external
D 06
probe is available)
D 08
System return water temperature
D 09
List of the last five anomalies (to scroll the list press "OK" (1)).
D 10
Anomaly list reset. Once "D 10" is displayed, press "OK".
D 14
Circulator pump flow rate
D 17
Zone 1 flow temperature (if configured)
D 20
System flow temperature
DHW 3-way (DHW = domestic hot water, CH = central heating) (if paired with a storage tank
D 22
unit)
D 24
Chiller circuit liquid temperature
D 25
Zone 2 flow temperature (if configured)
D 26
Probe for primary solar storage (puffer)
D 28
System circulator pump instantaneous speed
D 31
DHW integration function (if paired with a storage tank unit)
D 32
System integration function
D 34
Heat pump disabling
D 35
Solar system inlet
D 41
Relative humidity zone 1 (if zone 1 humidity sensor active)
D 42
Relative humidity zone 2 (if zone 2 humidity sensor active)
D 43
Zone 1 humidistat (if zone 1 humidistat active)
D 44
Zone 2 humidistat (if zone 2 humidistat active)
D 45
Dehumidifier zone 1
D 46
Dehumidifier zone 2
D 47
Zone 1 circulator pump
D 48
Zone 2 circulator pump
D 49
Central heating / cooling system separation 3-way (CL = cooling, HT = heating)
D 51
Zone 1 remote panel
Description
Range
-10 ÷ 130 °C
5 ÷ 55 °C
10 ÷ 55 °C
- 20 ÷ 50 °C
-10 ÷ 130 °C
-
-
0 ÷ 9999
0 ÷ 99 °C
-10 ÷ 130 °C
DHW- CH
-10 ÷ 130 °C
-10 ÷ 130 °C
-10 ÷ 130 °C
0 ÷ 100 %
OFF - ON
OFF - ON
OFF - ON
OFF - ON
0 ÷ 99 %
0 ÷ 99 %
OFF - ON
OFF - ON
OFF - ON
OFF - ON
OFF - ON
OFF - ON
CL - HT
OFF - ON
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magis pro 14 v2Magis pro 16 v2