Error
Anomaly signalled
Code
Safety thermostat
E 34
intervention Mixed
zone 2
Safety thermostat
intervention Mixed
E 35
zone 3
Low power supply
E 37
voltage
Safety thermostat
E 46
intervention zone 1
External probe
E 50
missing or faulty
Central heating
E 54
storage tank probe
anomaly (optional)
Mixed zone 1 probe
E 55
anomaly
Zone 1 device offline
E 121
alarm
Zone 2 device offline
E 122
alarm
Zone 3 device offline
E 123
alarm
Zone 1 room
E 125
temperature probe
anomaly
Zone 2 room
temperature probe
E 126
anomaly
(1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised After-Sales Technical Assistance Centre).
38
Cause
During normal operation, if an anomaly causes excessive
overheating of the flow temperature in the mixed zone 2,
the unit indicates the malfunction.
During normal operation, if an anomaly causes excessive
overheating of the flow temperature in the mixed zone 3,
the unit indicates the malfunction.
This occurs when the power supply voltage is lower than the
allowed limits for correct system operation.
During normal operation, if an anomaly causes excessive
overheating of the flow temperature in zone 1, the unit indi-
cates the malfunction.
In the event the external probe is not connected or is faulty,
the anomaly is indicated.
The central heating storage tank has an out of range resis-
tive value
If the board detects an anomaly on the mixed zone 1 probe,
the system cannot work in the affected area.
The device connected to zone 1 is offline
The device connected to zone 2 is offline
The device connected to zone 3 is offline.
The zone 1 room probe has an out of range resistive value
The zone 2 room probe has an out of range resistive value
Indoor unit status / Solution
The unit does not meet the zone
central heating requirement. (1)
The unit does not meet the zone
central heating requirement. (1)
If normal conditions are restored, the
system restarts without having to be
reset (1)
The unit does not meet the zone
central heating requirement (1).
Check the external probe connection.
The system continues to operate with
the external probe integrated in the
external unit (1).
In case of replacement of the external
probe, repeat the installation opera-
tions.
Puffer mode is disabled. (1)
(1)
(1)
(1)
(1)
(1)
(1)