1.20 CIRCULATION PUMP

The appliance is supplied with a variable speed pump which operates as follows:
- Fixed ("A 05" = 0): The pump speed is fixed and corresponds to parameter "A 04".
- ∆T constant ("A 05" = 5 K): the pump speed varies to maintain the ∆T = 5K constant between the system flow and return. Also, you
can adjust the pump operating range, by setting the maximum speed "A 04" and the minimum speed "A 03".
For proper system operation, make sure that the minimum flow rate in operating conditions never drops below 750 l/h.
Pump release.
If after a long period of inactivity, the circulator is blocked, adjust the screw in the centre of the head in order to manually release the mo-
tor shaft.
Take great care during this operation to avoid damage to the motor.
Head available to the Magis Pro 12-14 V2 system
140
130
120
110
100
90
80
Y1
70
60
50
40
30
20
10
10
0
0
0
Key (Fig. 20):
X1
= Flow rate (l/h)
Y1
= Head (kPa)
Y2
= Circulator pump absorbed power (W)
1
= Maximum speed (A04 = 75%)
2
= Minimum speed (A03 = 50%)
A
= Head available to the system
28
**
*
1
2
200
400
600
800
1000
1200
B
A
1400
1600
1800
2000
2200
2400
X1
B
= Absorbed power by the circulator (dotted area)
*
= Maximum head that can be set with A04 = 100% (for adjust-
ment refer to Parag. 3.9).
**
= Maximum speed that can be set with A04 = 100% (for adjust-
ment refer to Parag. 3.9).
140
130
120
110
100
90
80
Y2
70
60
50
40
30
20
10
10
0
2600
2800
3000
3200
3400
20