System Filling - Immergas MAGIS PRO 12 V2 Instructions And Recommendations

Hide thumbs Also See for MAGIS PRO 12 V2:
Table of Contents

Advertisement

Key (Fig. 11, 12, 13, 14, 15, 16)
1
- Central heating set
2
- Cooling set
Rxx
- Temperature control menu parameter
TE
- Outside temperature
TM
- Flow temperature
U 01
- Zone 2 flow temperature in "User" menu central heating
mode
U 02
- Zone 2 flow temperature in "User" menu cooling mode
U 03
- Offset value compared to the curve set by the external probe
on central heating zone 1
U 04
- Offset value compared to the curve set by the external probe
on central heating zone 2
U 05
- Offset value compared to the curve set by the external probe
on cooling zone 1

1.17 SYSTEM FILLING

Once the indoor unit is connected, fill the system using the filling cock (Par. 1.22).
The indoor unit has one incorporated automatic vent valve located on the circulator and another on the central heating manifold.
Make sure that the hoods are loosened.
The filling cock must be closed when the indoor unit pressure gauge indicates approximately 1.2 bar.
During these operations, enable the "Venting" functions by setting the "U 50" parameter to ON, which lasts about 18 hours
(Parag. 3.9).
System minimum water content.
Minimum water content favours the proper execution of defrosting cycles and operation in cooling mode.
To this end, the minimum amount of water to guarantee is 50 litres for any type of system and in any operating mode.
U 06
- Offset value compared to the curve set by the external probe
on cooling zone 2
U 14
- Zone 3 flow temperature in "User" menu central heating
mode
U 15
- Zone 3 flow temperature in "User" menu cooling mode
U 16
- Offset value compared to the curve set by the external probe
on central heating zone 3
U 17
- Offset value compared to the curve set by the external probe
on cooling zone 3
Zx
- Heating system zone
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magis pro 14 v2Magis pro 16 v2

Table of Contents