3.16 SOLAR PANELS COUPLING FUNCTION.

In the case of integration of the heating of the DHW with solar
panel systems, for correct use of the boiler in this condition, it
is necessary to set the parameter P3 (DHW thermostat) on "1".
3
b
1

3.17 CASING REMOVAL.

To facilitate boiler maintenance the casing can be completely
removed as follows (Fig. 39 / 40):
1 Unhook the decorative frame (a) from the relative lower retai-
ners.
2 Remove the decorative frame (a) from the casing (c).
3 Loosen the 2 front screws (b) that fix the casing on.
4 Loosen the 2 lower screws (d) that fix the casing on.
5 Pull the case towards yourself (c).
6 Push the case (c) upwards at the same time to release it from
the upper hooks.
Installation drawings key:
a
Unmistakeable component identification
1
Sequential identification of the operation to perform
2
b
3
c
a
39
45

Advertisement

Table of Contents