4.2.9 MEMORY ALL CLEAR (SP5-801)

NOTE: Memory All Clear mode resets all the settings and counters stored in the
NVRAM to the defaults, except for the following:
• Electrical total counter value (SP7-003)
• Machine serial number (SP5-811)
• Plug & Play brand name and production name setting (SP5-907)
• Some SBU settings (SP4-904-3, SP4-904-4, SP4-906, SP4-909)
• Language UK/TW Priority (SP5-916) – Asia and Taiwan version only
Normally, this SP mode should not be used. This procedure is necessary only after
replacing the NVRAM, or when the copier malfunctions because the NVRAM is
damaged.

Using a Flash Memory Card

1. Upload the NVRAM data to a flash memory card (see NVRAM Data Upload).
2. Print out all SMC data lists (SP mode 5-992).
NOTE: Be sure to print out all the lists. If the NVRAM data upload was not
completed, it is necessary to change the SP mode settings by hand.
3. Access SP mode 5-801.
4. Hold the "Original Type" key and the "OK" or é key at the same time. (If the
operation was successful, the beeper will sound 5 times. If it failed, the beeper
will sound only twice.)
5. Turn the main switch off and back on.
6. Download the NVRAM data from a flash memory card (see NVRAM Data
Download).

Without Using a Flash Memory Card

If there is no flash memory card, follow the steps below.
1. Print out all SMC Data Lists (SP mode 5-992).
2. Access SP mode 5-801.
3. Hold the "Original Type" key and the "OK" or é key at the same time. (If the
operation was successful, the beeper will sound 5 times. If it failed, the beeper
will sound only twice.)
4. Turn the main switch off and back on.
5. Do the printer and scanner registration and magnification adjustments (see
Replacement and Adjustment - Copy Adjustments).
6. Referring to the SMC data lists, re-enter any values that differ from the factory
settings. In particular, the values for SP4-904-1, SP4-904-2, SP4-905, and
SP4-907 must be re-entered.
7. Do the standard white level adjustment (SP4-908). (See Replacement and
Adjustment – Standard White Density Adjustment for details.)
8. Check the copy quality and the paper path, and do any necessary adjustments.