PRE-INSTALLATION INFORMATION
Sink specification guidelines
Using a specially designed test method, Dyson engineers
tested a wide range of sinks to assess their compatibility with
the Dyson Airblade Wash+Dry hand dryer. For recommended
sinks, please contact dyson
AU: 1800 426 337 or NZ: 0800 397 667
Porcelain or brushed metal sinks are ideal.
Sinks with highly polished surfaces should be avoided
e.g. reflective chrome.
Fig.1
350 mm minimum
350mm minimum
350mm minimum
Fig.3
385 mm minimum
385mm minimum
Sink dimensions
(All internal measurements unless otherwise stated)
Fig.1 Width of sink minimum: 350 mm, Front to back of sink minimum: 300 mm
Fig.2 Maximum depth of sink for Tall Neck Tap (WD05) only: 200 mm
(External measurement of vessel/pedestal sink.)
Tap mounting
The tap stem (measured from the outside diameter) should
be mounted 15-40 mm from the outside edge of the sink.
There should be a minimum of 290 mm between a tap centre
and a side wall. When multiple taps are installed side-by-side,
tap centres should be a minimum of 580 mm apart. This allows
sufficient space for mounting the motor bucket, as well as sufficient
shoulder room for users.
Fig.2
385mm minimum
Fig.3 Minimum distance from tap centre to top of sink (WD06 only) 100 mm.
Front edge of sink (all types – pedestal, recessed, slab) to wall minimum 385 mm.
Internal depth of sink minimum (for all taps): 100 mm
385mm minimum

Advertisement

loading

Summary of Contents for Dyson Airblade Wash+Dry WD05

  • Page 1 PRE-INSTALLATION INFORMATION Sink specification guidelines Tap mounting Using a specially designed test method, Dyson engineers The tap stem (measured from the outside diameter) should tested a wide range of sinks to assess their compatibility with be mounted 15-40 mm from the outside edge of the sink.
  • Page 2 Soap and locating the soap dispenser Do not place the downward facing water sensor of the tap For best user experience, Dyson recommends the use of gel soaps. over a reflective surface, such as the drainage hole. (Fig.4) The infrared sensing zone for air activation extends along each tap For complete instructions, please refer to the printed branch.
  • Page 3 Water drainage Base to back and front wall transition Due to high velocity air and water being in close proximity, The base to back and front wall transition should also be there is a chance of some water and soap dispersion outside considered.
  • Page 4 Sink access guidelines Mounting the motor bucket (WD04/WD05) It is recommended that the following guidelines are followed to Ensure 100 mm minimum clearance from bottom ensure there is sufficient access under the sink to allow for servicing of motor bucket to floor/wall. and installation to take place (Fig.10).
  • Page 5 Installing WD06 WD06 metal enclosure assembly The WD06 Dyson Airblade Wash+Dry hand dryer is designed Fig.12 so that the motor unit is located behind a stud wall within a metal enclosure which is supplied with the Dyson Airblade Wash+Dry hand dryer (Fig.12). The vertical wall studs must be constructed so as to allow the metal enclosure to be fitted between them (Fig.13).
  • Page 6 In some countries there are regulations or guidelines that require Heater temperature controlled water supply systems (such as that supplied to the Dyson Airblade Wash+Dry hand dryer) to be subjected to regular cleaning to minimise any biological growth. To enable you to meet these regulations, the Dyson Airblade Wash+Dry hand dryer has been designed and tested to withstand internal cleaning both with hot water up to 95°C and with sodium hypochlorite...
  • Page 7 A(i)
  • Page 8 A(ii) Clear zone 85mm min 3.3inch min 100mm min 3.9inch min...
  • Page 9 350mm min 13.7inch min 580mm min 290mm min 22.8inch min 11.4inch min 155mm max 6.1inch max 100mm min 3.9inch min 60mm 2.3inch 60mm 60mm 2.3inch 2.3inch 60mm 60mm 2.3inch 2.3inch 60mm 2.3inch...
  • Page 10 6° 60mm 60mm 60mm 60mm 2.3inch 2.3inch 2.3inch 2.3inch...
  • Page 12 0.19inch...
  • Page 13 100mm 3.9inch...
  • Page 14 clik clik clik clik clik clik...
  • Page 15 clik...
  • Page 16 clik clik clik clik clik...
  • Page 17 Dyson Customer care www.dyson.com (+44) 0800 345 7788 (+357) 24 532 220 (+81) 0120 295 731 (+351) 800 784 355 www.dyson.co.uk www.dyson.cy www.dyson.co.jp www.dyson.pt (+353) 01 401 8300 00800 777 55 777 (+82) 70 4066 0073 (+971) 4 507 6000 www.dyson.ie...
  • Page 18: Table Of Contents

    GB/ROI/IN/JM/MT/PH/SG Contents Important Safety Instructions In the box Pre-installation checks Installation Step-by-step Test installation Troubleshooting...
  • Page 19: Important Safety Instructions

    DO NOT USE ANY JET WASH EQUIPMENT FOR CLEANING ON OR ALL INSTALLATION AND REPAIR WORK (PLUMBING AND NEAR THIS UNIT ELECTRICAL) SHOULD BE CARRIED OUT BY A QUALIFIED PERSON OR DYSON SERVICE ENGINEER IN ACCORDANCE WITH CURRENT LOCAL CODES OR REGULATIONS. WARNING RISK OF ELECTRIC SHOCK!
  • Page 20: In The Box

    In the box Tools required: Small Phillips screwdriver 7mm slotted screwdriver 2.5mm slotted screwdriver Torx T15 screwdriver Tape measure and pencil Hand drill Suitable drill bit Pliers/wire strippers Knife Adjustable spanner...
  • Page 21: Mt Ph Sg

    Fig. compliance is the responsibility of the Dyson engineers tested a wide range of installer. Make sure that the unit is installed sinks to assess their compatibility with the It should also be located at least 60mm in compliance with all building codes and/ Fig.
  • Page 22 Ensure electricity and mixed water supplies water supply systems (such as that supplied to and drainage connections are available for the Dyson Airblade Wash+Dry hand dryer) to connection. Suitable isolation of the power be subjected to regular cleaning to minimise and water supplies must be in place to switch any biological growth.
  • Page 23: Step-By-Step

    Step-by-step Fig. 4 Water entry Water connection is made on the left hand side of the backplate. The water connection Preparing for installation of backplate can not be rotated within the backplate Remove the motor bucket from the backplate Fig. Fig.
  • Page 24 Fig. 11 Fig. 13 Remove the 2 x Phillips screws and unclip the solenoid from the backplate Fig. Connecting the mixed water supply Assembling the motor bucket Attach the water hose to the solenoid Fig. NOTE: Ensure water feed has been Hook the motor to the top of the electrics completely flushed of debris, copper cover.
  • Page 25: Test Installation

    – Ensure there is no plug in the sink and – Inspect filter and change if required. Contact Dyson Customer Care for further remove if plug is present. – Ensure that the hose is securely attached to support and information or online at –...