2.5 FAULT AND ANOMALY SIGNALS

The boiler signals any anomalies using a code shown on the boiler display (Fig. 52) according to the following table:
Error
Anomaly signalled
Code
No ignition block
01
Safety thermostat
function block (NTC
02
flow/return
overheating)
Flue safety thermostat
03
block
Contacts resistance
block / Damaged
04
hardware board
Delivery probe fault
05
(1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised Service Centre)
(2) The anomaly can only be verified in the list of errors in the "Information" menu
76
Cause
If room central heating or domestic hot water production is
requested, (when the boiler is paired with a storage tank
unit) the boiler does not switch on within the preset time.
Upon appliance commissioning or after extended down-
time, it may be necessary to eliminate the block.
During normal operation, if a fault causes excessive over-
heating internally, the boiler goes into overheating block.
During normal operation, if a fault causes excessive flue gas
overheating, the boiler blocks.
The P.C.B. detects a fault on the gas valve supply. Check its
connection. (the anomaly is detected and displayed only in
the event of a request). Once it has been established that the
fault is not related to the gas valve, the P.C.B. must be re-
placed if the fault does not disappear after pressing the Re-
set button.
The board detects an anomaly on the flow NTC probe.
Boiler status / Solution
Press the Reset button (1).
Press the Reset button (1).
Press the Reset button (1).
Press the Reset button (1).
The boiler does not start (1).