4.3 TECHNICAL DATA TABLE

Central heating nominal heat input
Minimum heat input
PoCentral heating nominal heat input with 20%H2NG gas
Minimum heat input with 20%H2NG gas
Central heating nominal heat output (useful)
Minimum heat output (useful)
*Effective thermal efficiency 80/60 Nom./Min.
*Effective thermal efficiency 50/30 Nom./Min.
*Effective thermal efficiency 40/30 Nom./Min.
Casing losses with burner On/Off (80-60°C)
Chimney losses with burner On/Off (80-60°C)
Efficiency at 100% heat output (η100) ref. UNI EN 15502-1
Efficiency at partial heat load (η30) ref. UNI EN 15502-1
Central heating circuit max. operating pressure
Maximum heating temperature
Adjustable central heating temperature (min. operating field)
Adjustable central heating temperature (max operating field)
Appliance water content
Head available with 1000 l/h flow rate
Weight of full boiler
Weight of empty boiler
Electrical connection
Nominal power absorption
Installed electric power
Equipment electrical system protection
Ambient operating temperature range
Ambient operating temperature range with antifreeze kit (optional)
NO
class
X
*Weighted NO
G20
X
Weighted CO G20
Weighted NO
G31
X
Weighted CO G31
Type of appliance
Market
Category
* Efficiencies and weighted NOx refer to the net calorific value.
The data relevant to domestic hot water performance refer to a dynamic inlet pressure of 2 bar and an inlet temperature of 15°C; the values
are measured directly at the appliance outlet considering that to obtain the data declared mixing with cold water is necessary.
For type C63 it is forbidden to install the appliance as it came out of the factory, in configurations that require shared flues in positive
pressure.
Configurations C
and C
(10)
(12)
The appliance is suitable for operation in a C
114
are only permitted with original, approved flue system
or C
system and only with the supply of methane gas (2H and 2E categories).
(10)
(12)
VICTRIX TERA V2 24
PLUS EU
kW
24,5
kW
4,5
kW
23,2
kW
4,3
kW
24,0
kW
4,3
%
97,8 / 96,6
%
106,5 / 107,6
%
108,0 / 108,4
%
0,36 / 0,10
%
0,02 / 2,10
%
97,5
%
109,6
bar
°C
°C
°C
l
3,3
kPa
24,4
kg
34,5
kg
31,2
V/Hz
A
0,7
W
90
IP
°C
°C
-
mg/kWh
39
mg/kWh
16
mg/kWh
33
mg/kWh
16
B23 B23p B33 B53 B53p C13 C33 C43 C53 C63 C83
-
C93 C13X C33X C43X C53X C63X C83X C93X
C(10)3 C(12)3 C(10)3X C(12)3X
VICTRIX TERA V2 35
PLUS EU
32,8
6,3
31,4
6,0
32,0
6,1
97,7 / 96,8
104,8 / 105,6
106,6 / 107,1
0,29 / 0,10
0,01 / 2,20
97,6
109,2
3,0
90
20
85
3,8
31,6
39,6
35,8
230 / 50
1,0
130
X5D
-5 ÷ 40
-15 ÷ 40
6
28
17
31
21
IE
II2H3P