3.23 ASSEMBLY OF MANIFOLD GASKET ON CONDENSATION MODULE

The operations described below must be performed after having removed the voltage from the
appliance.
After checking the integrity of the seals, proceed as follows if they need to be replaced:
Victrix Tera V2 24 Plus EU
1. Remove old seals.
2. Place the module gasket (1) radially on the edge of the condensation module flange (2).
3. Make sure that the gasket tab with number 4 printed on it is positioned in its seat on the module flange, identified by the number 4.
Every time the manifold is opened, the condition and integrity of the ceramic fibres must be verified and re-
placed, if necessary. The manifold gasket, on the other hand, must be replaced every 2 years. After replacing the
external silicone gasket, it is mandatory to check the fume tightness.
108