3.22 REPLACING THE MANIFOLD INSULATING PANEL
The operations described below must be performed after having removed the voltage from the
appliance.
Victrix Tera V2 24 Plus EU
1. To access the inside of the appliance, remove the casing as indicated in Paragr. 3.21.
2. Unscrew the 4 manifold fastening nuts (1, Fig. 79) and gently pull them out orthogonally towards yourself.
3. Unscrew the fixing screws (6) of the ignition and detection electrode (5) and remove it.
4. Remove the insulating panel (1) by actuating a blade (2) under its surface.
5. Remove the residue of the fixing adhesive from the surface of the manifold (3).
6. Replace the insulating panel (1).
The new insulating panel, used as a spare to replace the removed one, does not need to be fixed with glue as its shape with the in-
terference on the burner ensures correct coupling with the manifold.
7. Refit the ignition and detection electrode (5) using the previously removed screws (6) and replace the relative gasket (4).
Electrode distance
To regain optimal operation, make sure that the following variables are respected when refitting the electrodes.
106
2
1
6
5
4
3
1
73
74