Dirt separator kit
Hide thumbs Also See for VICTRIX PRO V2:

Advertisement

Mounting the dirt separator.
Assemble the nipples (3) on the dirt separator (4), making sure to interpose suitable sealing material such as oakum or similar.
Connect the pipe (2) and the dirt separator (4), previously assembled with the nipples (3), to the return (R) line of the boiler (7), making
sure to interpose the gaskets (1).
Connect the pipe (6) and the pipe (5) in sequence to the delivery line (M) of the boiler (7), making sure to place the gaskets (1) in between
as shown in Fig. 17.
N.B.: Choose the pipe (5) of the appropriate length according to the type of boiler (35-55-80-100-120-150-180) and the type of connection
to be made (left or right) (see Fig. 13, 14, 15 and 16).
After the 1st temperature test, check the tightness of all the pipes.
N.B.: the components downstream of the system, such as the expansion tank etc..., must be sized according to the flow rate of the system.
If assembling the kit with free outputs on the left side, perform the installation as shown in figure 18.
Attention: the VICTRIX PRO V2 boilers have an IPX5D electric insulation rating and can also be installed outdoors by means of the
relevant kits. However, if installed outdoors, the kit should be protected from the elements.
The boilers must be installed in the configurations and with their own original safety kits. The factory declines all liability whenever the
installer does not use the devices and approved original kits or uses them improperly.
1
M
6
7
R
1
2
1
5x
5x
LEFT OUTLET
Ref.
1
2
3
4
3
1
5A
5B
5C
6
4
7
2
6
Kit components description
44x34x2 gasket
Victrix Pro V2 BP set kit flow
pipe
Brass nipples G 1 1-2 G 2 mm
Victrix Pro V2 G2 R146MY018
dirt separator
DN40 G 1 1/2 L.199 pipe
DN40 G 1 1/2 L.289 pipe
DN40 G 1 1/2 L.111 pipe
Victrix Pro V2 dirt separator kit
flow pipe
Boiler
18
Q.ty
6
1
2
1
1
1
1
1
1
17