Download Print this page
Elkay EZH2O VRCGRNTLDWS C Series Installation & Use Manual
Elkay EZH2O VRCGRNTLDWS C Series Installation & Use Manual

Elkay EZH2O VRCGRNTLDWS C Series Installation & Use Manual

Bottle filling station and cooler

Advertisement

Quick Links

VRCGRNTLDWS*C
VRCGRNTL8WS*1C
LVRCGRNTLDWS*C
LVRCGRNTL8WS*1C
INSTALLATION & USE MANUAL
Manual de instalación y uso
Manuel d'installation et d'utilisation
EZH2O
Bottle Filling Station and Cooler
®
Estación de llenado de botella EZH2O
y enfriador
®
Station de remplissage de bouteille EZH2O
et refroidisseur
®
Page 1
1000001742 (Rev. N - 01/19)

Advertisement

loading

Summary of Contents for Elkay EZH2O VRCGRNTLDWS C Series

  • Page 1 VRCGRNTLDWS*C VRCGRNTL8WS*1C LVRCGRNTLDWS*C LVRCGRNTL8WS*1C INSTALLATION & USE MANUAL Manual de instalación y uso Manuel d’installation et d’utilisation EZH2O Bottle Filling Station and Cooler ® Estación de llenado de botella EZH2O y enfriador ® Station de remplissage de bouteille EZH2O et refroidisseur ®...
  • Page 2 VRCGRNTLDWS*C VRCGRNTL8WS*1C LVRCGRNTLDWS*C LVRCGRNTL8WS*1C Note: Danger! Electric shock hazard. Disconnect power before servicing unit. Nota: peligro! Peligro de descarga eléctrica. Desconecte antes de reparar la unidad. Remarque : Danger ! Risque d'électrocution. Débrancher avant de réparer l'appareil. Pictured is unit only without bottle filler. Uses HFC-134A refrigerant Usa refrigerante HFC-134A Utilise du fluide frigorigéne HFC-134A...
  • Page 3 VRCGRNTLDWS*C VRCGRNTL8WS*1C LVRCGRNTLDWS*C LVRCGRNTL8WS*1C STANDARD TWO-LEVEL INSTALLATION Fig. 2 Page 3 1000001742 (Rev. N - 01/19)
  • Page 4 VRCGRNTLDWS*C VRCGRNTL8WS*1C LVRCGRNTLDWS*C LVRCGRNTL8WS*1C IMPORTANT IMPORTANTE MPORTANT ALL SERVICE TO BE PERFORMED BY AN TODO EL SERVICIO DEBERÁ SER EFECTUADO POR TOUT ENTRETIEN DOIT ÊTRE EFFECTUÉ PAR AUTHORIZED SERVICE PERSON UNA PERSONA DE SERVICIO AUTORIZADA UN REPRÉSENTANT AUTORISÉ HANGER BRACKETS & TRAP INSTALACIÓN DE FIJADOR DE INSTALLATION DU SIPHON ET DU INSTALLATION...
  • Page 5 VRCGRNTLDWS*C VRCGRNTL8WS*1C LVRCGRNTLDWS*C LVRCGRNTL8WS*1C PUSH BUTTON MECHANISM MECANISMO DE BARRA DE EMPUJE MÉCANISME DU BOUTON-POUSSOIR Fig. 5 Fig. 6 Fig. 7 Page 5 1000001742 (Rev. N - 01/19)
  • Page 6 VRCGRNTLDWS*C VRCGRNTL8WS*1C LVRCGRNTLDWS*C LVRCGRNTL8WS*1C 7/16” BOLT HOLES FOR MOUNTING FASTENING UNIT TO WALL SCREWS TOP COVER UNIT CENTER LINE Fig. 9 Fig 8 BRACKET & SCREWS Fig. 10 Fig. 11 Bottle Filler Installation Instructions 1) Remove two (2) mounting screws with 5/32” Allen wrench holding top cover to Bottle Filler (See Fig. 9). Remove top cover. Note do not discard mounting screws, they will be needed to reinstall top cover.
  • Page 7 VRCGRNTLDWS*C VRCGRNTL8WS*1C LVRCGRNTLDWS*C LVRCGRNTL8WS*1C BF11 - BF12 PROGRAM SETTING THE CONTROL BOARD VERIFY CONTROL BOARD SOFTWARE Continued from below: 1) To verify the software program of the control board the unit will 2) When the display changes to “SETTINGS”, depress the button again. need to be shut down and restarted.
  • Page 8 VRCGRNTLDWS*C VRCGRNTL8WS*1C LVRCGRNTLDWS*C LVRCGRNTL8WS*1C OPERATION OF QUICK CONNECT FITTINGS OPERATION OF QUICK CONNECT FITTINGS BOTTLE FILLING UNIT SIMPLY PUSH IN SIMPLY PUSH IN TUBE IS SECURED PUSH IN COLLET TUBE IS SECURED PUSH IN COLLET TUBE TO ATTACH IN POSITION TUBE TO ATTACH IN POSITION TO RELEASE TUBE...
  • Page 9 VRCGRNTLDWS*C VRCGRNTL8WS*1C LVRCGRNTLDWS*C LVRCGRNTL8WS*1C OVERLOAD COLD CONTROL (WATER) COMPRESSOR RELAY Fig. 16 115V Wiring Dia gram Diagrama de cableado de 115 voltios schéma de câblage de 115 volts FIVE PIN CONNECTOR FOUR PIN MAIN BOARD CONNECTOR PIGGY BACK TERMINAL ON POWER CORD WHITE I.R.
  • Page 10 PRINTED IN U.S.A. INFORMATIONS POUR LE SERVICE PAR NUMERO SANS FRAIS 1.800.260.6640 IMPRESO EN LOS E.E.U.U. IMPRIMÉ AUX É.-U. ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 • www.elkay.com 1000001742 (Rev. N - 01/19) Page 10...