PLEASE READ THE FOLLOWING
• INSTALLATION INSTRUCTIONS FOR THE 4400FR FTN.
WITH 97243C SINGLE VALVE CONTROL ASSEMBLY ARE
LOCATED ON PAGES 2 - 5.
• INSTALLATION INSTRUCTIONS FOR THE 4400FR FTN.
WITH SANITARYFR1 VALVE ARE LOCATED ON PAGES
6 - 12.
INSTALLER
4400FR Fountains are among the easiest to install Fountains on the market today. To assure
you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS
BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE
WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After installation, leave
these instructions with the Fountain for future reference.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A
COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS
GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A
METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF
PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
Owners Manual
4400 Freeze Resistant Tubular Fountain
STOP!
INFORMATION!
IMPORTANT
IMPORTANT
4400FR-FTN
PAGE 1
97731C (Rev. J - 6/11)

Advertisement

loading

Summary of Contents for Elkay 4400FR-FTN Series

  • Page 1 4400FR-FTN Owners Manual 4400 Freeze Resistant Tubular Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION! • INSTALLATION INSTRUCTIONS FOR THE 4400FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY ARE LOCATED ON PAGES 2 - 5. • INSTALLATION INSTRUCTIONS FOR THE 4400FR FTN. WITH SANITARYFR1 VALVE ARE LOCATED ON PAGES 6 - 12.
  • Page 2 4400FR-FTN Owners Manual 4400 Freeze Resistant Tubular Fountain with 97243C Single Valve Control Assembly IMPORTANT! INSTALLER PLEASE NOTE Do not pull up on lines coming out of the PVC column. This raises the water valve above the frost line with disastrous results.
  • Page 3 4400FR-FTN SITE PREPARATION DETAIL FOR THE 4400FR FTN. WHEN USING 97243C SINGLE VALVE CONTROL ASSY. LEGEND A = ACCESS PANEL ( 8" X 10" ) E = 1-1/4" DRAIN TUBE B = 1" PVC DRAIN F = AIR CONTROL LINE C = PRESSURE FITTING 1-1/4"...
  • Page 4: Troubleshooting

    4400FR-FTN INSTALLATION INSTRUCTIONS FOR INSTALLING 97243C SINGLE VALVE CONTROL ASSY. 1. Prepare trench for water supply and waste drain lines (if required by local codes). The hole should be deep enough to accommodate the PVC column and 5 cubic feet of porous fill (large broken rock). Additional porous fill may be required due to local ground conditions. (See Site Preparation Detail below). 2.
  • Page 5 4400FR-FTN The following items are included with the 4400FR Fountain PARTS LIST ITEM NO. PART NO. DESCRIPTION 100147140560 Drain Gasket 75589C Gasket 101449542550 Clamp - Hose 101570540560 Drain Gasket 15009C Nipple Assy. - Bubbler 15014C Retaining Nut 40045C Hex Nut 1-5/16" 98118C Bubbler Assembly 45403C...
  • Page 6 4400FR-FTN Owners Manual 4400 Freeze Resistant Tubular Fountain with SanitaryFR1 Valve IMPORTANT! INSTALLER PLEASE NOTE Tubing must be cut to the right length. Do not coil any excess tubing or it will cause valve to malfunction. General Installation Tips 1. Prepare trench for water supply and waste drain lines. The hole should be deep enough to accommodate the PVC column. Additional porous fill and drain pipe may be required due to local ground conditions.
  • Page 7 4400FR-FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4400FR FTN. WHEN USING THE SANITARYFR1 VALVE FIG. 1 PAGE 7 97731C (Rev. J - 6/11)
  • Page 8 4400FR-FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4400FR FTN. WHEN USING THE SANITARYFR1 VALVE 1-1/4 DRAIN TUBE SUPPLIED WITH FTN. AIR GAP ASSY. SUPPLIED WITH VALVE 1-1/2 DRAIN TUBE SUPPLIED BY INSTALLER Detail A FIG. 2 LEGEND A = ACCESS PANEL ( 8" X 10" ) 97731C (Rev.
  • Page 9 4400FR-FTN FOUNTAIN CONNECTIONS PLUMBING CONDUIT (BY INSTALLER) TO VALVE FIG. 3 INSTRUCTIONS FOR CONNECTING TUBES FROM VALVE TO FOUNTAIN Step 1 - Insert the 1/8” O.D. tube (Label A) into the connector (provided with fountain). Insert the 1/8” O.D. tube coming from the fountain push button actuator into the connector.
  • Page 10 4400FR-FTN Stream Height Adjustment 3, 11 See Detail B FIG. 5 FIG. 4 Detail B 97731C (Rev. J - 6/11) PAGE 10...
  • Page 11 4400FR-FTN The Following Items are included with the SanitaryFR1 Valve PARTS LIST PART NO. DESCRIPTION ITEM NO. 110175443890 Hex Nut - 3/8-16 45806C Single Valve 50986C Regulator Holder 56082C Regulator Nut 56092C Poly Tubing - 1/4” (Cut To Length) - To Bubbler 56123C Poly Tubing - 1/8”...
  • Page 12 4400FR-FTN The Following Items are included with the 4400FR Fountain PARTS LIST ITEM NO. PART NO. DESCRIPTION 100147140560 Drain Gasket 100322740560 Washer 101570540560 Drain Gasket 15009C Nipple Assy. - Bubbler 15014C Retaining Nut 28467C Basin 40045C Hex Nut 1-5/16" 98118C Bubbler Assembly 45403C Push Button Actuator...