Elkay LZS8WS 2FQ Series Installation, Care & Use Manual
Elkay LZS8WS 2FQ Series Installation, Care & Use Manual

Elkay LZS8WS 2FQ Series Installation, Care & Use Manual

Bottle filling stations & coolers

Advertisement

Quick Links

LZS8WS*2FQ
INSTALLATION, CARE & USE MANUAL
EZ & LZ Series Bottle Filling Stations & Coolers
TM
TM
Page 1
1000002235 (Rev. B - 03/16)

Advertisement

loading

Summary of Contents for Elkay LZS8WS 2FQ Series

  • Page 1 LZS8WS*2FQ INSTALLATION, CARE & USE MANUAL EZ & LZ Series Bottle Filling Stations & Coolers Page 1 1000002235 (Rev. B - 03/16)
  • Page 2 LZS8WS*2FQ Note: Danger! Electric shock hazard. Disconnect power before servicing unit. Pictured is unit only without bottle filler. Uses HFC-134A refrigerant See Fig. 10 See Fig. 3 Fig. 1 1000002235 (Rev. B - 03/16) Page 2...
  • Page 3 LZS8WS*2FQ Fig. 2 Page 3 1000002235 (Rev. B - 03/16)
  • Page 4 LZS8WS*2FQ HANGER BRACKETS & TRAP INSTALLATION 1) Remove hanger bracket fastened to back of cooler by removing one (1) screw. 2) Mount the hanger bracket as shown in Figure 2. NOTE: Hanger Bracket MUST be supported securely. Add fixture support carrier if wall will not provide adequate support.
  • Page 5: Top Cover

    LZS8WS*2FQ 7/16” BOLT HOLES FOR MOUNTING FASTENING UNIT TO WALL TOP COVER SCREWS UNIT CENTER LINE Fig. 4 Fig. 5 BRACKET, WASHERS, Fig. 6 Fig. 7 & SCREWS Bottle Filler Installation Instructions 1) Remove two (2) mounting screws with 5/32” Allen wrench holding top cover to Bottle Filler (See Fig. 5). Remove top cover. Note do not discard mounting screws, they will be needed to reinstall top cover.
  • Page 6 LZS8WS*2FQ BF11 PROGRAM SETTING THE CONTROL BOARD VERIFY CONTROL BOARD SOFTWARE Continued from below: 1) To verify the software program of the control board the unit will 2) When the display changes to “SETTINGS”, depress the button again. need to be shut down and restarted. The chiller (if present) does The display will change to show not need to be shut down and restarted.
  • Page 7: Wall Mounting Plate

    LZS8WS*2FQ WALL MOUNTING PLATE BOTTLE FILLING UNIT Fig. 8 OVERLOAD COLD CONTROL PURPLE TO BOTTLE FILLER SHORT WHITE LEAD FROM POWER CORD SOLENOID VALVE RELAY TO "N" TERMINAL ON TO "L" TERMINAL ON POWER INLET POWER INLET TO "GROUND" TERMINAL ON POWER INLET Fig.
  • Page 8 LZS8WS*2FQ Basin Locknut BUBBLER DETAIL VANDAL RESISTANT BUBBLER DETAIL Fig. 10 Fig. 11 NOTE: When installing replacement bubbler and pedestal, tighten nut only to hold parts snug in position. Do Not Overtighten. Cleaning the strainer To clean the strainer, unscrew the cap of the solenoid valve.
  • Page 9 LZS8WS*2FQ OPERATION OF QUICK CONNECT FITTINGS OPERATION OF QUICK CONNECT FITTINGS SIMPLY PUSH IN SIMPLY PUSH IN TUBE IS SECURED TUBE IS SECURED PUSH IN COLLET PUSH IN COLLET TUBE TO ATTACH IN POSITION TUBE TO ATTACH IN POSITION TO RELEASE TUBE TO RELEASE TUBE PUSHING TUBE IN BEFORE PUSHING TUBE IN BEFORE...
  • Page 10 REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816 PRINTED IN U.S.A. ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 1000002235 (Rev. B - 03/16) Page 10...