To assure you install this model easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK
YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL
AND OTHER APPLICABLE CODES. After installation, leave these instructions
inside the fountain for future reference.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER
LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY
FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN,
CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL
CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS
INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO
ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
LJNED10_2AQ
IMPORTANT
FIG. 1
PAGE 1
19
26
26
10
1000002311 (Rev. C - 6/15)
FIG. 2

Advertisement

loading

Summary of Contents for Elkay LJNEM102QCDK

  • Page 1 LJNED10_2AQ Installation/Care/Use Manual Fully-Recessed Barrier-Free Water Cooler Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference.
  • Page 2 LJNED10_2AQ MOUNTING FRAME INSTALLATION INSTRUCTIONS 1. Cut a rectangular wall opening 25-1/8” (638mm) W x 53-1/2” (1359mm) H, 11-3/8” (289mm) above the floor line. Inside of this opening add (1) 1-1/2” (38mm) stud to create two openings: (1) 17-3/8” (441mm) W x 53- 1/2”...
  • Page 3: Plumbing Rough-In

    LJNED10_2AQ PLUMBING ROUGH-IN * NOTE: If wall opening height has been adjusted to meet local codes (see Step No. 1 of installation instructions), height dimensions must be adjusted accordingly. OPTIONAL WASTE TUBE LOCATIONS 14" 356mm 18" 8-1/4" MINIMUM DEPTH 457mm 210mm FINISHED WALL 17-1/2"...
  • Page 4 LJNED10_2AQ FILTER INSTALLATION INSTRUCTIONS Remove front panel of chiller. Note: For color images please visit www.elkay.com. Install 3/8" formed copper tube (item 2) to left side of filter head. Screw locknut hand-tight to seal. See Figures 5 and 18. Mount filter head to chiller using (3) screws (provided). See Figure 6.
  • Page 5 LJNED10_2AQ FOUNTAIN INSTALLATION INSTRUCTIONS Familiarize yourself with the mounting frame which should already be in place in the wall. If not, refer to the mounting frame installation instructions on page 2 before proceeding. Determine location of rough plumbing. At this point, you should decide which style trap you plan to use. For easier installation, we recommend the use of a swivel trap.
  • Page 6 LJNED10_2AQ TUBE ROUTING DIAGRAM REGULATOR ASSEMBLY SEE FIGURE 16 TO BUBBLER TO CUP FILLER CHILLER INLET CHILLER OUTLET FIG. 11 1000002311 (Rev. C - 6/15) PAGE 6...
  • Page 7 LJNED10_2AQ CUP DISPENSER INSTALLATION INSTRUCTIONS 1. The Cup Dispenser is designed to complement recessed drinking fountains. The fountain should already be installed before beginning installation. If not, refer to page 2 for your model. 2. Check wall opening to see if provisions have been made to accept this cup dispenser. If they have not, refer to page 2 for rough-in instructions.
  • Page 8: Troubleshooting And Maintenance

    LJNED10_2AQ TROUBLE SHOOTING AND MAINTENANCE Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a small round file not over 1/8” diameter or small diameter wire. CAUTION: DO NOT file or cut orifice material.
  • Page 9: Parts List

    Note: Screw the locknut hand tight to seal FIG. 18 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620 REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 PAGE 9 1000002311 (Rev. C - 6/15)