What's in the Package
Mounting bracket
Lower bracket
Backup Interface
SAFETY AND HANDLING INSTRUCTIONS
Read this entire document before installing or operating the Backup Interface (also referred to as BUI). Failure to do so or to follow any of the
instructions or warnings in this document can result in electrical shock, serious injury, or death, or may damage the Backup Interface and other
property, it can also lead to warranty void.
Do not discard this document! After installation, keep it adjacent to the Backup Interface for future reference!
Before operating the Backup Interface and inverter, ensure that they are properly grounded. The Backup Interface and inverter must be
connected to a grounded, metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and
connected to the equipment grounding terminal or lead.
Opening the Backup Interface and repairing or testing under power must be performed only by qualified service personnel familiar with the
Backup Interface.
WARNINGS
!
The backup systems generate power to the home when the grid is off or when the main circuit breaker is also OFF. Please make sure
to attach the warning sticker (of Dual Supply warning) in a visible place at the main circuit cabinet. For additional safety, we
recommend installing an external shutdown press button to make sure the Inverter is also off when the main circuit breaker is off.
For installation instructions please refer to the Inverter installation guide.
Main connection scheme
1
4
4
Warning Label
Mounting the Backup
Interface
1.
Select an installation location. Make sure you have enough
3
space between the Backup Interface and other objects to
securely access all its interfaces.
2.
Install the mounting bracket to the wall and secure it with
2-4 screws. If using only 2 screws, use left and right ones.
3.
Hang the Backup Interface on the mounting bracket.
2
4.
Hang the lower bracket on the hook behind the bottom
glands, secure it to the wall with a screw.
Quick Installation Guide
Required Tools
Drill
Torque
wrench
X 3
Mounting
screws and wall
plugs
This symbol on the product or in the accompanying documentation denotes a hazard. It calls attention to a procedure that, if not
correctly performed or adhered to, could result in injury or loss of life. Do not proceed beyond a warning note until the indicated
conditions are fully understood and met.
This symbol on the product denotes risk of electric shock due to stored energy. Before handling the product, wait for at least 5
seconds after disconnecting it from all sources of energy.
DANGER!
Before opening the covers and connecting the grid, please make sure that the main CB and the Inverters are OFF.
Bottom interface of the Backup Interface
Load section
Grid section
2
SolarEdge Home
Backup Interface, Single
Phase
BI-EU1P
for use with the SolarEdge Home Hub
Inverter, Single Phase
Level
Phillips
Watchmaker flat
screwdriver
screwdriver
Pencil
M4, M5 Allen
CAT6 cable
keys
Removing the covers
WARNING
It is forbidden and dangerous to open the upper section.
Only the lower section is for user interface usage.
1
1.
Using M5 Allen key, release six screws and remove the Backup
Interface front cover.
2.
Using M4 Allen key, release two screws and remove the Backup
Interface internal lower cover.
3.
Make sure the ON/OFF switch is in the OFF position.
2
!
3
OFF

Advertisement

loading

Summary of Contents for SolarEdge BI-EU1P

  • Page 1 SolarEdge Home Quick Installation Guide Backup Interface, Single Phase Support Contact Information In case of any technical issues with SolarEdge BI-EU1P products, please contact us at: https://www.solaredge.com/service/support for use with the SolarEdge Home Hub © SolarEdge Technologies, Ltd.
  • Page 2 Connect the ground wire first. Torque – 6Nm. Connect the wires Ground (yellow), Line (brown), and Neutral (blue) to their respective terminals. If your system doesn’t use Solaredge Home Network, connect the Backup Interface to your inverter using a CAT5 E or a CAT6. Open the communication gland and insert the communication cable, close the gland.