1.17 CONCENTRIC VERTICAL KIT INSTALLATION

Type C configuration, sealed chamber and fan assisted
Concentric vertical intake and exhaust kit.
This vertical terminal is connected directly to the outside of the building for air intake and flue gas exhaust.
The vertical kit with aluminium tile enables installation on terraces and roofs with a maximum slope of 45% (approx. 25°) and
the height between the terminal cap and half-shell (374 mm for Ø 60/100 and 260 mm for Ø 80/125) must always be observed.
Mounting the vertical kit with aluminium tile Ø 60/100 (Fig. 20)
1. Install the concentric flange (2) on the flue exhaust of the appliance, positioning gasket (1) with the circular projections downwards in
contact with the appliance flange.
2. Tighten the concentric flange with the screws in the kit.
3. Replace the tiles with the aluminium sheet (4), shaping it to ensure that rainwater runs off.
4. Position the fixed half-shell (6) on the aluminium tile.
5. Insert the intake-exhaust pipe (5).
6. Fit the Ø 60/100 concentric terminal pipe with the male side (5) (smooth) into the flange (2) up to the end stop, making sure that the
wall sealing plate has been fitted (3); this will ensure sealing and joining of the elements making up the kit.
When the appliance is installed in areas where very rigid temperatures can be reached, a special anti-freeze kit is available that
can be installed as an alternative to the standard kit.
5
4
3
2
1
32
C
33
7
6
20
The kit includes (Fig. 20):
N°1 Gasket (1)
N°1 Female concentric flange (2)
N°1 Wall sealing plate (3)
N°1 Aluminium tile (4)
N°1 Concentric intake/exhaust pipe Ø 60/100 (5)
N°1 Fixed half-shell (6)
N°1 Mobile half-shell (7)