Appendix A: Troubleshooting

This appendix describes how to troubleshoot StorEdge related errors.

Communication Troubleshooting

When a battery and a meter are connected (2 devices connected to the same bus), the following should 
appear in the Communication status screen:
w w w w w w w
R S 4 8 5 - 1 < M L T > < 0 2 > < 0 2 >
Z i g B e e
Device type, number and protocol are displayed
incorrectly
If one or more of the following occurs, the meter(s) or the battery are   n ot communicating with the 
inverter:
 
MLT (Multi) is not displayed as the device type (under Dev) 
l
 
The number of devices under Prot (protocol) or under ## does not match the number of connected 
l
devices
 
The number   u nder Prot (configured devices) does not match the number under ## (communicating 
l
devices) 
Check the following: 
 
The meter and battery configuration is as described in Configuring the RS485 Bus for Battery and Meter 
l
Connection on page 62.
 
The wiring between the StorEdge Connection Unit,   t he battery and the meter is correct (refer to 
l
Figure 19).
 
There are no loose connections at any of the system components connectors. 
l

Troubleshooting Ethernet Communication

When using Ethernet communication, use the Server Communication Status window to identify the 
location of the error:
S e r v e r : L A N
S t a t u s :
x x x x x x x x
< E R R O R
xxxxxxxx is a string of 1s and 0s showing an eight-bit communication connection status. 1 indicates OK 
and 0 indicates an error. 