3.18 INTEGRATION WITH SYSTEM EXTERNAL ELECTRICAL RESISTANCE.

External electrical resistances can operate in parallel with the internal resistance.
They are activated with the same logic as the internal resistance.
For the electrical connection see the reference wiring diagram (Fig. 12).
If one or more external electric resistances are installed in combination with one of the two-zone kits (supplied by Immergas), integration
must be installed between the UI MHPM indoor unit and the distribution kit.
If one or more external resistances are installed, the parameter must be adjusted
Special parameters / Parameter 2
by entering the total installed power value (multiplied by a factor of 10).

3.19 ZONE 2/3 SAFETY THERMOSTAT FUNCTION

In case of zone 2 or zone 3 installation, a control on the zone flow temperature is enabled which prevents the production of water above a
certain temperature.
It is possible to modify these limits through the parameters
Special parameters / Safety therm. Zone 2
Special parameters / Safety therm. Zone 3

3.20 CONJUNCTION MODE

In case of simultaneous DHW (Domestic hot water) and system request, the system decides which to service to perform on the basis of an
alternating logic determined by the system.
It is possible to modify this logic, so that the system simultaneously deals with both services, using the generators available.
Operation in this mode can be activated by editing the following parameters:
System definition / Concomitant mode
Moreover, also the DHW electrical resistance needs to be enabled:
Integration / Enable DHW integr.
97