3.17 INTEGRATION WITH SYSTEM INTERNAL ELECTRICAL RESISTANCE.

The heat pump can be added with a system electrical resistance (optional) to be installed inside the appliance, to have an alternative
source of energy available for use in central heating mode.
Enabling the electrical resistance is done via a single parameter.
Modifying the parameter
Integration / Enable heat.integr.
it is decided whether to activate only the heat pump or only the resistance or both to perform the Central heating mode.
Modifying the parameter
Integration / CH integration mode
it is decided whether to activate the heat pump and the resistance in an alternate or simultaneous manner.
Modifying the parameter
Integration / CH wait time
you decide the time after which the electrical resistance is activated at the same time as the heat pump if the set flow setpoint is not
reached.
In caso di modo integrazione alternativo, il tempo di attesa non ha influenza sull'algoritmo di funzionamento.
In normal operation, the integration resistance is only activated when the outdoor temperature is below the parameter
Integration / Min. integration temp.:
- with alternative mode, only the resistance is activated;
- with simultaneous mode, the resistance and heat pump are activated simultaneously after the heating wait time.
In case of simultaneous DHW (Domestic hot water) and system requests, the system alternates the two operating modes according to the
times set in the parameters:
Integration / Time preceding DHW
Integration / Pre-heating time
The first served operating mode, in case of contemporaneity, is decided with the parameter:
Configuration / Priority