Immergas MAGIS HERCULES PRO MINI 6 Instructions And Recommendations page 60

Hide thumbs Also See for MAGIS HERCULES PRO MINI 6:
Table of Contents

Advertisement

Error
Anomaly signalled
Code
De-aeration in
139
progress
Errore Dominus
142
offline
Recirculation probe
143
alarm
DHW maximum time
177
alarm
Block: anti-legionella
178
cycle not successful
Liquid phase probe
179
alarm
Outdoor unit in test
183
mode
Request out of
188
operating range
Time out alarm with
189
communication
board
Alarm low liquid
phase probe
195
temperature
High flow temp. block
196
Communication
board configuration
197
error
(1) If the shutdown or fault persists, contact an authorised company (e.g. Authorised After-Sales Technical Assistance Centre).
60
Cause
Deaeration function in progress
Communication with Dominus is offline
The board detects an anomaly on the D.H.W. recirculation
probe
Domestic hot water production is not met within the
pre-established time (see parameter P014)
The anti-Legionella cycle is run without success within the
pre-established time (see parameter P013)
The board detects an anomaly on the liquid phase NTC
probe.
A signal notifies that the outdoor unit is in test mode.
A request is made with the outdoor temperature exceeding
the operating limits (Parag. 1.16)
If communication between the printed circuit boards is
lost, an anomaly is signalled.
Too low temperature is detected in the liquid phase
An excessively high temperature is detected on the heat
pump flow circuit
An incorrect communication board configuration has
been detected
Appliance status / Solution
No demand can be made until the end
of the function in progress (1)
(1)
The system does not recirculate DHW
(1)
The system continues to operate with
non-optimal performance (1)
Press the Reset button (1)
The system does not start (1).
During this time, room air condition-
ing and domestic hot water produc-
tion requirements cannot be met
The system does not start (1).
Wait for the outdoor unit to be
restored within operating limits.
The system does not start (1).
Check communication between the
P.C.B. and the interface board.
Check that the cooling circuit is
working properly (1).
Check the hydraulic circuit (1).
The system does not start (1).