Menu item
Defines the time spent at minimum operating temperature
Min dwell time set
during the active function
Rise gradient
Defines the ascent gradient of the temperature
Defines
Max dwell time set
operating temperature during the active function
Fall gradient
Defines the descent gradient of the temperature
Defines the minimum delivery temperature of the
Minimum flow set
screed heater function
Defines the maximum delivery temperature of the
Maximum flow set
screed heater function
Activation
Activation of the screed heater function
Menu item
HP
Board revisions
Meters
Menu item
Flow temperature
Return temperature
Compress.outlet temp.
Compress. drain temp.
Compress.int.temp.
Expan.valve pos.
Heat exch.cool.temp.
Coil temperature
Outdoor HP temp.
HP frequency
HP request mode
HP Status
System resistance
DHW resistance 1
System state
Integration state
Output status
Disable HP
Inverter current
Fan speed (H)
Fan speed (L)
HP Setpoint
54
Menu / User / Screed heater
Description
the
time
spent
Menu / Information
Defines the heat pump operating parameters.
This displays the system board revisions.
This displays the operating data.
Menu / Settings / HP
Heat pump flow temperature
Heat pump return temperature
Outdoor unit compressor temperature
Outdoor unit compressor discharge temperature
Not present
Outdoor unit expansion valve position
Coolant temperature inside the plate heat exchanger
Outdoor unit coil temperature
Outside temperature
Heat pump frequency
Status of the request to heat pump
Heat pump status
System resistance active control
Standard DHW (Domestic hot water) resistance active control
Technical parameter (only for Immergas Assistance)
Technical parameter (only for Immergas Assistance)
Technical parameter (only for Immergas Assistance)
Heat pump activation/deactivation status
Outdoor unit inverter current
Outdoor unit high fan speed
Outdoor unit low fan speed
Request setpoint to heat pump
Range
1 - 7 days
3 ÷ 30 °C/g
at
maximum
1 - 14 days
3 ÷ 30 °C/g
20 ÷ 45 °C
25 ÷ 55 °C
Yes / No
Description
Description
Customised
Default
value
3
30
4
30
25
45
No