Menu item
Information
Settings
Menu item
Room temperature
Room humidity
Dew temperature
Set room temperature
Room humidity set
Flow set
Flow temperature
Operation status
Menu item
Setting of the zone 3 operating mode.
Off = zone in OFF mode
Operation mode
Auto = Zone in Automatic mode
Manual = zone in manual mode
C.H.
Cooling
Dehumidification
Menu item
Room setpoint in central heating zone 3 Comfort mode (Auto
Comfort Set
mode)
Room setpoint in central heating zone 3 Economy mode (Auto
Economy Set
mode)
Manual set
Room setpoint in central heating zone 3 manual mode
Flow set
Flow setpoint set for zone 3 in central heating / C.H.
Flow offset
Offset temperature for central heating zone 3
(*) if present.
48
Zones / Zone 3 (*)
This displays the system operating data.
Defines the operating parameters to manage the zone 3.
Zones / Zone 3 (*) / Information
Room temperature on zone 3
Zone 3 room humidity
Zone 3 dew temperature
Room setpoint set on zone 3
Room humidity setpoint set on zone 3
Flow setpoint on zone 3
Flow temperature set on zone 3
Description of the zone 3 operating mode
Off = zone in OFF mode
Economy = Zone in economy mode
Comfort = zone in comfort mode
Manual = zone in manual mode
Zones / Zone 3 (*) / Settings
Description
Zones / Zone 3 (*) / Settings / C.H.
Description
Description
Description
Range
Default
Off / Manual /
Auto
Auto
Range
Default
10 ÷ 35 °C
20
5 ÷ 30 °C
16
5 ÷ 35 °C
20
10 – 65 °C
40
- 9 ÷ + 9°C
Customised
value
Customised
value
0