By associating a calendar with the relevant zone program, it is possible to determine the time slots for activating the central heating /
C.H. comfort set. The time slots not set, correspond to the central heating / C.H. economy set.
When the detected room temperature is below the central heating / C.H. set active at that moment, the appliance is activated in central
heating / C.H. mode.
Adjustment OFF
Central heating / C.H. always off.
• In the second case, the system works in the following way:
Manual adjustment (Man)
The central heating / C.H. demand is activated according to the closing of the TA contact of the relative zone.
Automatic adjustment (Auto)
The central heating / C.H. demand is activated according to the closing of the TA contact of the relative zone, during zone presence in
the comfort band.
Adjustment OFF
Central heating / C.H. always off.
Cooling
It is possible to set the cooling activation parameters for each individual zone in three different ways: MANUAL, AUTOMATIC, OFF.
The selection is made by entering the "Zones"
Settings / Operation mode
There are two types of requests:
- Request from room temperature in the presence of remote control
Abilitazioni / Enable remote contr. = Probe / Panel
- Request from TA (room thermostat)
Enablings / Enable room thermostat = Yes
• In the first case, the system works in the following way:
Manual adjustment (Man)
The cooling request is adjusted according to a fixed room setpoint
Cooling / Manual set
When the room temperature is higher than the manual cooling set, the appliance is started in cooling mode.
Automatic adjustment (Auto)
There are two reference setpoints:
Cooling / Comfort Set
Cooling / Economy Set
By associating a calendar with the relevant zone program, it is possible to determine the time slots for activating the cooling comfort
set. The time slots not set, correspond to the cooling economy set.
When the detected room temperature is above the cooling set active at that moment, the appliance is activated in cooling mode.
Adjustment OFF
Cooling always off.
• In the second case, the system works in the following way:
Manual adjustment (Man)
The cooling demand is activated according to the closing of the TA contact of the relative zone.
Automatic adjustment (Auto)
The cooling demand is activated according to the closing of the TA contact of the relative zone, during zone presence in the comfort
band.
Adjustment OFF
Cooling always off.