DHW
The domestic hot water can be produced with the heat pump or with electrical resistance.
The system automatically manages the activation of the generators to heat up the domestic hot water in the storage tank.
During activation, 'DHW underway' appears on the display.
It is possible to set the domestic hot water temperature adjustment in two ways: MANUAL or AUTOMATIC.
The selection is made by entering the menu "DHW" ("DHW" button) and setting the parameter "Set Management".
Manual adjustment (Man)
Adjustment of the DHW temperature in MAN mode is done via the "DHW Set" knob (Fig. 28) or by changing the value "Manual set"
within the "DHW" menu.
Confirmation can take place in two ways: by pressing the OK button or by waiting two minutes after changing the value.
Automatic adjustment (Auto)
The AUTOMATIC DHW temperature adjustment involves setting "Comfort set" and "Economy Set" parameters in the "DHW" menu
and choosing the calendar inside the menu:
Clock and programs / DHW Program
In the selected time slots, the DHW set will be automatically set to the "Comfort Set" value; outside these, the set DHW will be set to
"Economy Set" value.
It is possible to temporarily modify the DHW set by setting a manual value using the "Set DHW" knob (Fig. 28).
This setting will be lost when the time slot is next changed.
DHW (Domestic hot water) Boost
Activating the "DHW (Domestic hot water) Boost" function via the menu
DHW / Boost Function = On
DHW (Domestic hot water) operation takes place with the contribution of both the heat pump and the electrical resistance, with a logic
that minimises storage tank charging time.
Central heating
It is possible to set the central heating / C.H. activation parameters for each individual zone in three different ways: MANUAL, AUTO-
MATIC, OFF.
The selection is made by entering the "Zones"
Settings / Operation mode
There are two types of requests:
- Request from room temperature in the presence of remote control
Information / Enable remote contr. = Probe / Panel
- Request from TA (room thermostat)
Enablings / Enable room thermostat = Yes
• In the first case, the system works in the following way:
Manual adjustment (Man)
The central heating / C.H. request is adjusted according to a fixed room setpoint
C.H. / Manual set
When the room temperature is lower than the manual central heating / C.H. set, the appliance is started in central heating / C.H.
mode.
Automatic adjustment (Auto)
There are two room temperature setpoints:
C.H. / Comfort Set
C.H. / Economy Set
menu and after having selected the zone of interest, access the menu