The power supply cable (l) must be laid as shown (Fig. 9).
l
9
If the power supply cable is damaged, it must be replaced by a special cable or assembly, which
are only available from the manufacturer or its Authorised After-Sales Technical Assistance
Centre.
It is recommended to contact a qualified company (e.g. the Authorised After-Sales Technical
Assistance Centre) for replacement to avoid a hazard.
To protect from possible dispersions of DC voltage, it is necessary to provide a type A differen-
tial safety device.
The power supply cable must be connected to a 230V ±10% / 50Hz mains supply respecting L-N
polarity and earth connection; this network must also have a multi-pole circuit breaker with
class III overvoltage category in compliance with installation regulations.