Indoor Unit Hydraulic Connection; Connecting The Chiller Line - Immergas MAGIS HERCULES PRO MINI 6 Instructions And Recommendations

Hide thumbs Also See for MAGIS HERCULES PRO MINI 6:
Table of Contents

Advertisement

1.5

INDOOR UNIT HYDRAULIC CONNECTION

3 and 8 bar safety valve
The appliance safety valves outlet must be connected to a draining funnel.
Otherwise, the appliance's manufacturer declines any responsibility in case of flooding if the drain valves cut.
A treatment of the heating and water system water is required, in compliance with the technical standards in force, in order to protect the
system and the appliance from deposits (e.g. scale), slurry or other hazardous deposits.
Water connections must be made in a rational way using the couplings on the indoor unit template.
The manufacturer declines all liability in the event of damage caused by the installation of an automatic filling system.
In order to meet the system requirements established by EN 1717 in terms of pollution of drinking water, we recommend installing the
IMMERGAS anti-backflow kit to be used upstream of the cold water inlet connection of the indoor unit. We also recommend using cat-
egory 2 heat transfer fluid (ex: water + glycol) in the internal unit primary circuit (heating and/or cooling circuit), as defined in standard
EN 1717.
In order to preserve the proper functioning of the manifold within the hydraulic circuit, it is necessary for the inspection Y-fil-
ter to work in a horizontal position.
1.6

CONNECTING THE CHILLER LINE

As far as connecting the chiller line is concerned, all the instructions contained in the outdoor unit instructions booklet must be fol-
lowed.
Make the connections directly on the indoor unit couplings (Pos. 1 and 2, Fig. 3).
12
1
2
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magis hercules pro mini 9Uimhpm6Uimhpm9

Table of Contents