4
TECHNICAL DATA
4.1
TECHNICAL DATA TABLE
The following data refers to product data.
Nominal data for low temperature applications (A7/W35) *
Nominal central heating output
Absorption
COP
Nominal data for low temperature applications (A35/W18) *
Nominal cooling output
Absorption
EER
Nominal data for intermediate temperature applications (A7/W45) **
Nominal central heating output
Absorption
COP
Nominal data for intermediate temperature applications (A35/W7) **
Nominal cooling output
Absorption
EER
Nominal data for medium temperature applications (A7/W55) ***
Nominal central heating output
Absorption
COP
* Central heating mode status: heat exchanger water inlet/remains at 30 °C/35 °C, outdoor air temperature 7 °C db/6 °C wb. Performance
in compliance with EN 14511.
Cooling mode status: heat exchanger water inlet/remains at 23 °C/18 °C, outdoor air temperature 35 °C. Performance in compliance with
EN 14511.
* Central heating mode status: heat exchanger water inlet/remains at 40 °C/45 °C, outdoor air temperature 7 °C db/6 °C wb.
Cooling mode status: heat exchanger water inlet/remains at 12 °C/7 °C, outdoor air temperature 35 °C. Performance in compliance with
EN 14511.
*** Central heating mode status: inlet/remains at 47 °C/55 °C, outdoor air temperature 7 °C db/6 °C wb. Performance in compliance with
EN 14511.
MAGIS HERCULES
PRO MINI 6
kW
6,00
kW
1,22
kW/kW
4,92
kW
6,50
kW
1,47
kW/kW
4,42
kW
5,40
kW
1,51
kW/kW
3,58
kW
4,70
kW
1,44
kW/kW
3,26
kW
4,80
kW
1,81
kW/kW
2,65
MAGIS HERCULES
PRO MINI 9
9,00
1,87
4,81
8,70
2,11
4,12
8,60
2,33
3,69
6,50
1,95
3,33
8,00
2,73
2,93
105