Download Print this page

Elkay LZS8WS 2GQ Series Installation & Use Manual page 4

Advertisement

HANGER BRACKETS & TRAP
INSTALLATION
1) Remove hanger bracket fastened to back of cooler by removing one (1) screw.
2) Mount the hanger bracket as shown in Figure 2.
NOTE: Hanger Bracket MUST be supported securely. Add fixture support car-
rier if wall will not provide adequate support. Anchor hanger securely to wall
using all six (6) 1/4 in. dia. mounting holes.
IMPORTANT:
5-7/8 in. (150mm) dimension from wall to centerline of trap must be maintained
for proper fit.
INSTALLATION OF COOLER
3) Hang the cooler on the hanger bracket. Be certain the hanger bracket is
engaged properly in the slots on the cooler back as shown in Figure 2.
4) Remove the four (4) screws holding the lower front panel at the bottom of
cooler. Remove the front panel by pulling straight down and set aside.
5) Connect water inlet line--See Note 4 above.
6) Install trap. Remove the slip nut and gasket from the trap and install them
on the cooler waste line making sure that the end of the waste line fits into
the trap. Assemble the slip nut and gasket to the trap and tighten securely.
IMPORTANT:
If it is necessary to cut the drain, loosen the screw at the black
rubber boot and remove tube, check for leaks after re-assembly.
7) Plug in electrical power. Unit must have
electrical power to have water flow.
START UP
Also See General Instructions
8) Stream height is factory set for 35 PSI supply.
this, adjust screw located on the right knee clearance area.
raise stream and CCW adjustment will lower stream. For best adjustment,
stream should hit basin approximately 6-1/2" (165mm) from bubbler on the
downward slope of the basin.
NOTE: If continuous flow occurs at the end of the compressor cycle, turn cold
control counterclockwise 1/4 turn.
9) Replace the front panel ensuring that the metal wrapper is secured inside of
the upper shroud. Replace all four screws previously removed.
CLEANING
Warm, soapy water or mild household cleaning products can be used to clean
the exterior panels of the EZ coolers. Extra caution should be used to clean
the mirror finished stainless steel panels. They can be easily scratched and
should only be cleaned with mild soap and water or Windex glass cleaner and
a clean, soft cloth. Use of harsh chemicals or petroleum based or abrasive
cleaners will void the warranty.
Service Instructions
Lower and Upper Shroud
To access the refrigeration system and plumbing connections, remove four screws from bottom
of cooler to remove the lower shroud. To remove the upper shroud for access to the pushbars,
regulator, solenoid valve or other components located in the top of the unit, remove lower shroud,
disconnect drain, remove four screws from tabs along lower edge of upper shroud, unplug two wires
and water tube.
Bubbler
To remove the bubbler, first disconnect the power supply. The underside of the bubbler can be
reached through the access panel on the underside of the upper shroud. Remove the access panel
by removing the retaining screw. To remove the bubbler, loosen locknut from the underside of the
bubbler and remove the tubing from the quick connect fitting per the Operation Of Quick Connect
Fittings section in the General Instructions. After servicing, replace the access panel and retaining
screw.
Switches Behind the Push Bar
The regulator in an EZ cooler is always held fully open by the use of a single regulator nut. Water is
not dispensed until the pushbar is depressed to activate a switch which then opens a solenoid valve.
When installing the regulator nut,
the regulator spring must be depressed while turning the nut.
To remove sidebars, from the inside compress the flared tabs and pull out carefully. To reinstall side
pushbars, the front of the pushbar is inserted first. While keeping the switch depressed, snap the
rear of the pushbar into position.
1000002246 (Rev. D - 06/23)
LZS8WS*2GQ
If supply pressure varies greatly from
CW adjustment will
11
8
19
6
12
R E G ULA TO R
A S SE M B LY
S N A P
View of Underside of Basin Shroud
Vista de la parte inferior de la cuenca cubierta
Vue de dessous du bassin du Saint-Suaire
Stream Height Adjustment Location
Ubicación de ajuste de altura de corriente
Emplacement de réglage hauteur Stream
Page 4
11
26, 29
2
26
26
12
A LIG N M E N T
N O TC H
S N A P
A LIG N M E N T
P E G
Fig. 3