Summary of Contents for Elkay LZS8WS 2GQ Series

  • Page 1 LZS8WS*2GQ INSTALLATION & USE MANUAL EZ & LZ Series Bottle Filling Stations & Coolers Patent zurn-elkay.com/patents WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov Page 1 1000002246 (Rev.
  • Page 2 LZS8WS*2GQ Note: Danger! Electric shock hazard. Disconnect power before servicing unit. Pictured is unit only without bottle filler. Uses HFC-134A refrigerant See Fig. 10 See Fig. 3 Fig. 1 1000002246 (Rev. D - 06/23) Page 2...
  • Page 3 LZS8WS*2GQ Fig. 2 Page 3 1000002246 (Rev. D - 06/23)
  • Page 4 LZS8WS*2GQ HANGER BRACKETS & TRAP INSTALLATION 1) Remove hanger bracket fastened to back of cooler by removing one (1) screw. 2) Mount the hanger bracket as shown in Figure 2. NOTE: Hanger Bracket MUST be supported securely. Add fixture support car- rier if wall will not provide adequate support.
  • Page 5 LZS8WS*2GQ 7/16” BOLT HOLES FOR MOUNTING FASTENING UNIT TO WALL TOP COVER SCREWS UNIT CENTER LINE Fig. 4 Fig. 5 BRACKET & SCREWS Fig. 7 Fig. 6 Bottle Filler Installation Instructions 1) Remove two (2) mounting screws with 5/32” Allen wrench holding top cover to Bottle Filler (See Fig. 5). Remove top cover. Note do not discard mounting screws, they will be needed to reinstall top cover.
  • Page 6 LZS8WS*2GQ BF11 - BF12 PROGRAM SETTING THE CONTROL BOARD VERIFY CONTROL BOARD SOFTWARE Continued from below: 1) To verify the software program of the control board the unit will 2) When the display changes to “SETTINGS”, depress the button again. need to be shut down and restarted.
  • Page 7: Wall Mounting Plate

    LZS8WS*2GQ WALL MOUNTING PLATE BOTTLE FILLING UNIT Fig. 8 OVERLOAD COLD CONTROL PURPLE TO BOTTLE FILLER SHORT WHITE LEAD FROM POWER CORD SOLENOID VALVE RELAY TO "N" TERMINAL ON TO "L" TERMINAL ON POWER INLET POWER INLET TO "GROUND" TERMINAL ON POWER INLET Fig.
  • Page 8 LZS8WS*2GQ Basin Locknut BUBBLER DETAIL VANDAL RESISTANT BUBBLER DETAIL Fig. 10 Fig. 11 NOTE: When installing replacement bubbler and pedestal, tighten nut only to hold parts snug in position. Do Not Overtighten. SM O O TH (B LA C K ) LE A D TO "L"...
  • Page 9 PULLING IT OUT HELPS TO PULLING IT OUT HELPS TO RELEASE TUBE RELEASE TUBE Fig. 14 Scan for trouble shooting and to sign up for auto replenishment of authentic Elkay filters. 3/8” Water Inlet Filter Detail Fig. 13 FILTER PARTS LIST ITEM NO.
  • Page 10 FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816 REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640 PRINTED IN U.S.A. • ELKAY MANUFACTURING COMPANY • 1333 BUTTERFIELD ROAD,SUITE 200 • DOWNERS GROVE, IL 60515 • 630.574.8484 www.elkay.com 1000002246 (Rev. D - 06/23) Page 10...

This manual is also suitable for: