Indigo Status Registers; Notification And Error Bits; Table 16 Modbus Status Registers (Read-Only); Table 17 Bits In Register E001 Hex - Vaisala Indigo 202 User Manual

Digital transmitter with wlan configuration interface
Hide thumbs Also See for Indigo 202:
Table of Contents

Advertisement

Indigo 202 (WLAN interface) User Guide
A.2 Indigo Status Registers
The following table describes the status information provided in Indigo status registers
(transmitter, probe, and relay statuses). For more details on the high-level transmitter and
probe statuses reported in register E000
Table 16 Modbus Status Registers (Read-Only)
Address
(Hexadecimal)
E000
hex
E001
hex
E011
hex
E012
hex
A.2.1 Notification and Error Bits
The status register (E000
present:
0
No issues
1
Info
2
Warning
3
Error
Additional details about the status reported in the register E000
16-bit register E001
hex
Table 17 Bits in Register E001
Bit in E001
hex
0 (0000
)
hex
1 (0001
)
hex
2 (0002
)
hex
70
hex
Register Description
Status
Notification and error
bits
Relay A status
Relay B status
) can report that one of the following notification types is
hex
, as described in the following table.
hex
Meaning
No errors
WLAN on
Probe error
, see
Notification and Error Bits (page
Data Format
16-bit
16-bit
enum
enum
Notes
Wireless configuration interface is
activated and can be connected to.
Connect to Indigo's wireless
configuration interface and review
the error information in the Status
menu. Check display messages.
M211966EN-D
70).
Notes
0 = Status OK
1 = Info
2 = Warning
3 = Error
Provides additional details on the
high-level status reported in
register E000
. See
Notification
hex
and Error Bits (page
70).
0 = Relay is not active
1 = Relay is activated
0 = Relay is not active
1 = Relay is activated
can be provided in the
hex

Advertisement