/(→P. ##) Indicates reference information. Indicates a screen item or button name. Abbreviation The following abbreviation is used for simplicity in this manual. microSD card: Indicates microSD, microSDHC, and microSDXC memory cards. RICOH SC-20 Quick Start Guide Rev 1.0 2/30...
Contents PACKAGE CONTENTS .............................. 4 NAMES OF PARTS ..............................5 OVERVIEW OF SC-20..............................8 SYSTEM CONFIGURATION DIAGRAM ........................10 When connecting the AC adapter ..........................10 SCREEN DESCRIPTION ............................11 Main Screen ................................11 FLOW UP TO THE OPERATION ..........................13 INSTALLATION: STEP 1 (INSTALLATION AND CONNECTIONS) ...............
Attaching a Lens / Installing the Unit (→P. The following can be downloaded from our website. [Software]: https://industry.ricoh.com/en/support/fa_camera_lens/download/soft/ SC-20 Work Instructions Editor (PC software) [Manual]: https://industry.ricoh.com/en/support/fa_camera_lens/download/manual/ SC-20 Operating Instructions SC-20 Quick Start Guide ...
When pressed for approximately 4 seconds: Forcibly turns off the power. Power LED lamp (green) Lights when the power turns on. ④ Flashes while the workflow is stopped. Lens mount C mount ⑤ Card slot microSD ⑥ RICOH SC-20 Quick Start Guide Rev 1.0 5/30...
Page 6
② ① ③ ④ ⑤ ① External connector ② USB Type-A connector LAN connector ③ HDMI connector ④ USB Type-C connector (USB Power Delivery supported / DisplayPort Alternate Mode not ⑤ supported) RICOH SC-20 Quick Start Guide Rev 1.0 6/30...
Page 7
Bottom of unit: ① ② ② ③ Tripod mount screw hole ① M4 screw holes ② Tripod positioning hole ③ RICOH SC-20 Quick Start Guide Rev 1.0 7/30...
3. Overview of SC-20 SC-20 can be used to judge the degree of similarity of a master image and camera image. It supports automatic judgment by the pattern matching function and manual judgment by visual checking. SC-20 has three work modes. The matching mode is described in the Quick Start Guide.
Page 9
When the inversion of each similarity judgment logic is set (when [Inversion] is set for [Similarity]), an arrow ( ) is displayed at the left center of the check point image. If you are using any other mode (check mode, data input mode), refer to “SC-20 Operating Instructions”. RICOH SC-20 Quick Start Guide Rev 1.0 9/30...
HDMI cable USB hub USB Type-C 100 to 240 V AC AC cord USB cable cable 50/60 Hz AC adapter USB mouse USB keyboard For other connections, refer to “SC-20 Operating Instructions”. RICOH SC-20 Quick Start Guide Rev 1.0 10/30...
④ ⑤ ⑥ ⑦ ⑧ ⑨ For details on each item, refer to “SC-20 Operating Instructions” (Menu). Menus Configure settings and perform operations from each menu. ① Status display area Displays the progress of the job, alias settings, external control ②...
Page 12
Job result display area ⑧ Displays the job result OK/FAIL count. Inspection step display area Displays the inspection steps. ⑨ RICOH SC-20 Quick Start Guide Rev 1.0 12/30...
Register the job ID, instruction step, instruction step file, inspection step, and work mode to create a workflow. STEP 4: Other Settings Configure various settings. Operation/adjustments (administrator user) Operate or stop the workflow and make adjustments to the parameters. RICOH SC-20 Quick Start Guide Rev 1.0 13/30...
5 megapixel lens (manual diaphragm lens for image processing) 5MX series Align the screw(s) (sold separately) with the tripod mount screw hole or M4 screw holes on the bottom of the unit and then fix the unit to the installation location. RICOH SC-20 Quick Start Guide Rev 1.0 14/30...
Connect the AC adapter to the USB Type-C connector on the rear of the unit. Connect the AC adapter and AC cord and connect to a power supply (100 to 240 V AC, 50/60 Hz). RICOH SC-20 Quick Start Guide Rev 1.0...
The [Initial Settings] screen can also be displayed from the [System Settings] menu after logging in. Click to shut down the system. Click [Save]. 17). The Login screen appears after restarting the device (→P. RICOH SC-20 Quick Start Guide Rev 1.0 16/30...
In this manual, the state in which login is performed with a general user ID is called the [User Mode] and the state in which login is performed with the administrator user ID is called the [Administrator Mode]. RICOH SC-20 Quick Start Guide Rev 1.0...
[>]: Advances the list to the next page. Register at least one user each in [Administrator user] and [General user]. Click the [Create new user] button. The [User Registration] screen appears. RICOH SC-20 Quick Start Guide Rev 1.0 18/30...
Page 19
If this checkbox is selected, the user is registered as an “Administrator user”. Password Set the password of the administrator user in 1 to 32 characters. Input is mandatory. When the input is complete, click the [Create] button. RICOH SC-20 Quick Start Guide Rev 1.0 19/30...
Create the instruction step file with the “Work Instructions Editor”. − “SC-20 Work Instructions Editor User's Guide” STEP 2: Registering a Job ID (→P. Registering job IDs enables workflows to be managed by IDs. Either register a new job ID or copy and register an existing job ID.
Click the camera image capture button on the main screen. Specify the save destination and file name to save the file. If necessary, repeat steps 2 and 3 to register the master image. Camera image area Camera image capture button RICOH SC-20 Quick Start Guide Rev 1.0 21/30...
Job ID control [Enable]: If this checkbox is selected, the job ID can be specified through ③ job ID input during the workflow execution (→P. 26). RICOH SC-20 Quick Start Guide Rev 1.0 22/30...
To create a workflow related to an instruction step file, create instruction steps and register the instruction step file. Multiple instruction steps (instruction step files) can be set for each workflow. “SC-20 Work Instructions Editor User's Guide” Select a job ID from the [Job ID List] on the [Job ID Settings] screen. Click [Add] under [Instruction Steps].
If you select this checkbox, the setting of [Standard Time] and [Upper Limit Time] is disabled. (The workflow is not judged as FAIL even if the job time exceeds the [Upper Limit Time].) RICOH SC-20 Quick Start Guide Rev 1.0 24/30...
Page 25
I/O Settings ...] (also set the corresponding [EXTOUT] number in [External I/O Settings]). Set the parameters for each mode. For details, refer to “SC-20 Operating Instructions”. When the settings are completed, click [Apply]. The settings are saved. If necessary, repeat steps 2 to 10 to register the inspection steps.
The job ID and reference ID are recorded in the job log. If you click [Cancel] on the [Change Job ID] screen or [Change Reference ID] screen, the workflow stops. RICOH SC-20 Quick Start Guide Rev 1.0 26/30...
The “X / X Instruction Step” indicates the “Executed number of instruction steps / Total number of instruction steps”. The “X / X Inspection Step” indicates the “Executed number of inspection steps / Total number of inspection steps”. RICOH SC-20 Quick Start Guide Rev 1.0 27/30...
Page 28
This information is reset when logging out or changing Job ID. You can also make the setting to not reset the number of executions when logging out or changing Job Camera image area Displays the camera image. ⑧ RICOH SC-20 Quick Start Guide Rev 1.0 28/30...
IEEE is a trademark of The Institute of Electrical and Electronic Engineers, Inc. All other product names or names are trademarks or registered trademarks of the respective companies. 14. Inquiries RICOH Industrial Solutions Inc. https://www.rins.ricoh.co.jp/en/contact/ June 2023 RICOH SC-20 Quick Start Guide Rev 1.0...
Page 30
Revision History Rev. Date Changes Note June 14, 2023 New issue RICOH Industrial Solutions Inc. RICOH SC-20 Quick Start Guide Rev 1.0 30/30...