Summary of Contents for Elkay EZH2O VRCGNDWS C Series
Page 1
VRCGNDWS*C VRCGN8WS*1C LVRCGN8WS*1C INSTALLATION, CARE & USE MANUAL Manual de Instalación, Cuidado y Utilización Manuel d’installation/entretien/utilisation EZH2O Bottle Filling Station and Cooler ® Estación de llenado de botella EZH2O y enfriador ® Station de remplissage de bouteille EZH2O et refroidisseur ®...
Page 2
VRCGNDWS*C VRCGN8WS*1C LVRCGN8WS*1C Note: Danger! Electric shock hazard. Disconnect power before servicing unit. Nota: peligro! Peligro de descarga eléctrica. Desconecte antes de reparar la unidad. Remarque : Danger ! Risque d'électrocution. Débrancher avant de réparer l'appareil. Pictured is unit only without bottle filler. Uses HFC-134A refrigerant Usa refrigerante HFC-134A Utilise du fluide frigorigéne HFC-134A...
Page 4
VRCGNDWS*C VRCGN8WS*1C LVRCGN8WS*1C IMPORTANT IMPORTANTE MPORTANT ALL SERVICE TO BE PERFORMED BY AN TODO EL SERVICIO DEBERÁ SER EFECTUADO POR TOUT ENTRETIEN DOIT ÊTRE EFFECTUÉ PAR AUTHORIZED SERVICE PERSON UNA PERSONA DE SERVICIO AUTORIZADA UN REPRÉSENTANT AUTORISÉ HANGER BRACKETS & TRAP INSTALACIÓN DE FIJADOR DE INSTALLATION DU SIPHON ET DU INSTALLATION...
Page 5
VRCGNDWS*C VRCGN8WS*1C LVRCGN8WS*1C PUSH BUTTON MECHANISM MECANISMO DE BARRA DE EMPUJE MÉCANISME DU BOUTON-POUSSOIR Fig. 5 Fig. 6 Page 5 1000001741 (Rev. G - 11/16)
Page 6
VRCGNDWS*C VRCGN8WS*1C LVRCGN8WS*1C MOUNTING 7/16” BOLT HOLES FOR SCREWS FASTENING UNIT TO WALL TOP COVER UNIT CENTER LINE Fig. 8 Fig. 7 BRACKET, WASHERS, Fig. 9 Fig. 10 & SCREWS Bottle Filler Installation Instructions 1) Remove two (2) mounting screws with 5/32” Allen wrench holding top cover to Bottle Filler (See Fig. 9). Remove top cover. Note do not discard mounting screws, they will be needed to reinstall top cover.
Page 7
VRCGNDWS*C VRCGN8WS*1C LVRCGN8WS*1C BF11 - BF12 PROGRAM SETTING THE CONTROL BOARD VERIFY CONTROL BOARD SOFTWARE Continued from below: 1) To verify the software program of the control board the unit will 2) When the display changes to “SETTINGS”, depress the button again. need to be shut down and restarted.
VRCGNDWS*C VRCGN8WS*1C LVRCGN8WS*1C OPERATION OF QUICK CONNECT FITTINGS OPERATION OF QUICK CONNECT FITTINGS SIMPLY PUSH IN SIMPLY PUSH IN TUBE IS SECURED PUSH IN COLLET TUBE IS SECURED PUSH IN COLLET WALL MOUNTING PLATE TUBE TO ATTACH IN POSITION TUBE TO ATTACH IN POSITION TO RELEASE TUBE TO RELEASE TUBE...
Page 9
VRCGNDWS*C VRCGN8WS*1C LVRCGN8WS*1C OVERLOAD COLD CONTROL (WATER) COMPRESSOR RELAY Fig. 15 115V Wiring Diagram Diagrama de cableado de 115 voltios schéma de câblage de 115 volts FIVE PIN CONNECTOR FOUR PIN MAIN BOARD CONNECTOR PIGGY BACK TERMINAL ON POWER CORD WHITE I.R.
Page 10
INFORMATIONS POUR LE SERVICE PAR NUMERO SANS FRAIS 1.800.260.6640 PRINTED IN U.S.A. IMPRESO EN LOS E.E.U.U. IMPRIMÉ AUX É.-U. ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 1000001741 (Rev. G - 11/16) Page 10...