1.5 INSTALLATION OPERATIONS OF WIRELESS ROOM PROBE AND CONCENTRATOR.
N.B.: the support for wall installation is the same both for fixing the wireless room probe and the concentrator.
Concentrator fastening:
1) Separate the fixing support from the cover of the Concentrator by prying with a screwdriver in the appropriate recess. Manually pull the cover outwards to
separate it from the support (Fig. 4).
2) Install the concentrator support (2) fixing it to the wall using the expansion anchors (1) and the supplied screws (3) (Fig. 5). The support can also be fixed
inside the boiler by proceeding as (Fig. 6) follows:
- remove the grid (2), unscrewing the screws (2) and fix the support (3) with the two screws (4) supplied as indicated in figure 6.
N.B.: before fixing the support, it is advisable to provide for the passage of the electrical connection cable (5) inside the slots.
3
Fig. 5
3
2
1
2
2
5
1
5
4
1
Fig. 4
4
3
2
Fig. 6