Step 3: Verifying Proper Activation And Commissioning - SolarEdge SE K Series Installation Manual

Three phase inverters with synergy technology
Hide thumbs Also See for SE K Series:
Table of Contents

Advertisement

Communication
Communication settings can be configured only after communication connections are
complete. Refer to Setting Up Communication with the Monitoring Platform on page 61.
From the Commissioning menu, select Monitoring Communication > Auto Select.
SetApp will automatically detect your connection method. Follow the on-screen
instructions to complete the configuration and establish communication with the
monitoring platform.
From the Commissioning menu, Select Site Communication to configure
communication between multiple SolarEdge devices or external non SolarEdge
devices, such as batteries or data loggers.
For more information on the Monitoring Platform, refer to "The Monitoring
Platform" section and to the Monitoring Platform web page at:
https://www.solaredge.com/products/pv-monitoring#/
Power Control
Power control options are detailed in the Power Control Application Note , available on
the SolarEdge website at:
note_power_control_configuration.pdf.
For P(Q) diagram refer to:
note_p_q_diagram_of_se_inverters_en_and_na.pdf.
NOTE
SolarEdge inverters with "Grid Support" functionality (as marked on the
inverter certification label), are compliant with UL 1741 Supplement A. The
functionality is built into the inverter and no additional external device is
required.
Step 3: Verifying Proper Activation and
Commissioning
 1. Select Information and verify that the correct firmware versions are installed on
each inverter.
 2. Select Status and verify that inverter is operating and producing power.
 3. Verify that additional configurations were properly set by viewing the relevant
Status screens.
 4. Verify that the green inverter LED is steadily lit.
Your SolarEdge power harvesting system is now operational.
Three Phase Inverters with Synergy Technology PN: SExxK-xxxxIxxxx
Chapter 6: Activating, Commissioning and Configuring the
https://www.solaredge.com/sites/default/files/application_
https://www.solaredge.com/sites/default/files/application_
System   79

Advertisement

Table of Contents
loading

This manual is also suitable for:

Se43.2kSe50kSe66.6kSe80kSe100kSe110k ... Show all

Table of Contents