NOTE
tion of the water system.
• Since the temperature sensor connected in the control panel is used to detect the room temperature, the control panel
(4) must be located in the room where the oor heating circuits and the fan coils are installed and far from the heat-
ing source.
e correct con guration must be applied in the control panel (Chap. 10.5 Settings on eld/Temp. Type
Setting).
e rst setpoint is the water temperature that can be set on the home page of the control panel, the second
setpoint is calculated based on the climatic curves, the target temperature of the outlet water is the highest of these
two setpoints.
e unit switches o when the room temperature reaches the target temperature.
Operation of the pump and space heating.
e pump (1.7) and (10) will operate when there is a heating demand from A and/or B.
when the room temperature of zone B is lower than the setpoint on the control panel.
to reach the required water ow temperature.
e pump (23.1) will operate
e heat pump will start running
-