GENERAL INTRODUCTION.

• Magis M4-30 block heat pumps are used both for heating and cooling applications and for domestic hot water tanks.
ey can be coupled with fan coils, oor heating applications, low-temperature high-e ciency radiators, domestic hot
water tanks and solar kits.
e unit is supplied with a control panel.
NOTE
e maximum length of the wiring that guarantees communication between the heat pump and the control panel is
50 m.
-
e power cables and communication wires are laid separately and cannot be placed in the same duct. Otherwise there
would be electromagnetic interference.
with the refrigerant pipe which at high temperatures could damage the wires.
-
e communication wires must be in shielded lines, including the line that goes from the heat pump to the control
panel.
1) Heat pump capacity.
2) Required heating capacity (depending on site).
3) Additional heating capacity supplied by a backup heater.
Domestic hot water tank (optional)
A domestic hot water storage tank can be connected to the unit (with or without tank booster heater (TBH)
e tank booster heater (TBH) must be installed below the temperature probe (T5)
e heat exchanger (coil) must be installed below the temperature probe.
Room thermostat (optional)
e room thermostat can be connected to the unit (the room thermostat must be far away from the heating source when
the installation place is chosen).
Solar kit (optional)
A solar kit can be connected to the appliance for the domestic hot water tank.
e unit has a freezing prevention function using the heat pump to keep the water system safe from freezing in all condi-
tions. Since a power failure could occur while the unit is unattended, it is recommended to empty the system (if there is no
glycol in the water). (Chap. 9.4.4 Anti-freeze protection of water circuit).
e power cables and wires for communication must not come into contact
Capacità/carico
Tbivalente
Serbatoio
Sonda di
probe (T5)
temperatura (T5)
Serpentino
Uscita
Resistenza
elettrica sanitario
H)
(TBH)
Ingresso